3590EGT 3GD Touchscreen Indicator for ATEX 2 and 22 Zones
Standard Features
- 5,7' colour touch screen display
- Multilanguage software
- 15-key alphanumerical waterproof keyboard
- 3-way control light
- Selectable QWERTY, AZERTY o QWERTZ keyboard integrated in the touch screen
- Stainless steel waterproof enclosure, with new IP68 protection system
- Dimensions: 280x143x185mm
- Suitable for use on the table, column or wall
- Real time clock and permanent data storage
- Fitted alibi memory, integrated on the motherboard
- Slot for built-in micro SD for recording the configuration, logos, and customized screens (upon request)
- Functions available with DINITOOLS utility
- Configuration, data entry and print formatting
- Recording and filing of all the information on PC
- Complete retrieval of the configuration
- Instrument calibration with numeric values
- Customization of the screens - 24-bit A/D converter, 4 channels, up to 3200 conv./sec. and up to 8 signal linearisation points
- 4 independent analogue channels for reading of the weight
- Connection with up to 16 analogue load cells of 350 Ohm (45 load cells of 1000 Ohm)
- Up to 10.000e OIML or 3 x 3000e @ 0,3 µV/e CE-M legal for trade
- Up to 1.000.000 displayable divisions for internal factory use, with internal resolution up to 3.000.000 points
- Connectable to printers and labellers with free programmation of the printout formats
- Power supply from 110-240Vac line or external rechargeable battery (recharge in safety zone).
3590EGT 3GD Touch Screen Indicator for ATEX 2 and 22 Zones
Weight indicator with a big touch screen display, for ATEX 2 & 22 areas classified at risk of explosion. Protection methods according to:
- ATEX II 3G Ex nR IIB T6 Gc X for gases
- ATEX II 3D Ex tc IIIC T85°C Dc IP68 X for dust.
Suitable for advanced industrial applications, it's fitted with 3 serial ports, configurable printouts and integrated alibi memory. CE-M approvable (OIML R-76 / EN 45501).
3590EGT 3GD Touch Screen Indicator for ATEX 2 and 22 Zones Specifications
I/O Section:
|
Available Languages:
|
Main Certifications:
Application Software:
|
Parts
Part # | Description |
---|---|
Available versions | |
3590EGTC3GD | Colour Touch Screen indicator, ATEX 3GD, with AF01 software. Stainless steel waterproof IP68 case. Protection degree: ATEX II 3G Ex nR IIB T6 Gc X for gases and ATEX II 3D Ex tc IIIC T85øC Dc IP68 X for dust. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT). |
Options
Part # | Description |
---|---|
Optional power supply cords | |
EXACB4 | 4x0.5 mmý armoured cable (suitable for Ex zones). PVC inner sheath. Armour: galvanised steel wire braid. Outer sheath PVC, diameter 7.3 mm. Temperature range: -30 / +80 øC. Minimum bending radius >/= 10 x O.D. _/m |
Available firmwares | |
AF02 | Software for piece/quantity counting. |
AF03GT | Software for weighbridges, vehicle In/Out. For 3590 "TOUCH SCREEN" weight indicators. |
AF04GT | Software for statistical checking of prepackaged goods. For 3590 "TOUCH SCREEN" weight indicators. |
AF05 | Software for price computing and industrial labelling. |
AF08 | Software for static wheel and axle weighing with 2 or more pads. |
AF09 | Software for dynamic and static axle weighing with 1 or 2 pads. |
BATCH1 | Software for single product dosage systems in loading and unloading. |
BATCH | Software for multicomponent dosage systems in loading and unloading. NOTE: For 3590, IOEXPB expansion board is required. |
Software to fill in the databases | |
DBM | PC software for quick filling out of the databases. For 3590Exx and CPWExx instruments (the price is intended for the license to manage one scale). |
Junction Box / Boards - Load Cell cables | |
3590E4CH | Built-in board for multiple quick scale connection. |
JB4QA | ATEX equalisation box made of ABS IP67, for up to 4 cells. 4 + 1 fairleads. Marking: ATEX II 2G Ex ib IIC T6 Gb for gases, ATEX II 2D Ex tb IIIC T115øC Db IP65 for dust. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT). |
JB4QAI | ATEX equalisation box made of stainless steel IP66 for up to 4 cells. 4 + 1 fairleads. Marking: ATEX II 2G Ex ib IIC T6 Gb for gases, ATEX II 2D Ex tb IIIC T115øC Db IP65 for dusts. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT). |
LCCB | Shielded cable 6x0.25 mmý (suitable for Ex zones). PVC inner sheath. Tinned copper braid shielding. PVC outer sheath, diameter 5.8 mm. Temperature range: -40 / +80 øC. Minimum bending radius >/= 6 x O.D. _/m |
LCCBA | Armoured cable 6x0.25 mmý (suitable for Ex zones). PVC inner sheath, diameter 5mm. Iron-zinc alloy armour. Transparent PVC outer sheath, 8 mm diameter. Temperature range: -15 / +70 øC. Minimum bending radius >/= 5 x O.D. _/m |
Approval | |
KCEM | Plates and Welmec form for legal trade use of a scale. NET PRICE. Service available in combination with a Dini Argeo indicator. |
ECEM-AU | Single platform/scale legal-for-trade approval for Australia. |
ATEX battery and battery charger | |
BP6ESTATEX3GD | IP65 stainless steel, external ATEX battery pack, for 2 and 22 zones. Marking: ATEX II 3G Ex ec IIC T6 Gc X for gas and ATEX II 3D Ex tc IIIC T85øC Dc IP65 X for dust. For Dini Argeo ATEX 3GD instruments. ATTENTION: rechargeable in safe zone only, connectable and disconnectable from the weighing system also in hazardous area. (Battery charger not included). |
BTCB3GD | Cable for BP6ESTATEX3GD battery connection. |
BP6CB | Battery charger for safe area, for BP6ESTATEX3GD ATEX battery. |
Declaration of ATEX conformity | |
DCATEX3590E3GD | Declaration of ATEX conformity of the assembly. Ex II 3G IIB T6 Gc X and Ex II 3D IIIC T115øC Dc X system, with relative label of whole system, for ATEX certified (3590EGTC3GD) or NOT ATEX certified Dini Argeo indicator (in the latter case to be installed in a safe area) connected to a mechanical structure with ATEX load cells (each cell must be certified with CCATEX or CCATEX3GD option). Provided with descriptive document of the assembly and ATEX EU declaration of conformity of the assembly (EN, DE, FR, ES and IT). |
Storing the weighs (only at time of order) | |
SWM | "WeiMonitor" PC program to monitor and record in real time weighs performed on the connected scale (the price is intended for the license to manage one scale). |
Communication Interfaces | |
OBRF2G4-USB | External 2.4 GHz radio frequency module, USB cable l=1m. Power supply directly from the USB port. Max. functioning distance, in appropriate environmental and installation conditions: 45 m indoors, 140 outdoors. 39 configurable channels. |
ETHD | Built-in Ethernet interface. Speed from 10 to 100 Mbps, TCP, UDP, IP, ARP, ICMP, Ethernet Mac protocols. |
OBWIFI3GD-4 | WIFI module for ATEX zones, with ABS IP66 case, 3 m shielded cable, and power supply from indicator. Protection: ATEX II 3G Ex ec IIB T6 Gc X for gases and ATEX II 3D Ex tc IIIC T85øC Dc IP66 X for dust. Max. functioning distance, in appropriate environmental and installation conditions: 30m indoors, 70m outdoors. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR and IT). |
Fieldbus interfaces | |
PROFINET1S | RS485 to ProfiNET interface, for DIN rail mounting. With UL marked PCB, Terminal block, plastic box and labels (if expected). |
ETHERNETIP1S | RS485 to Ethernet IP interface, for DIN rail mounting. With UL marked PCB, Terminal block, plastic box and labels (if expected). |
ETHERCAT1S | RS485 to EtherCAT interface, for DIN rail mounting. With UL marked PCB, Terminal block, plastic box and labels (if expected). |
DEVICENET1S | RS485 to DeviceNET interface, for DIN rail mounting. With UL marked PCB, Terminal block, plastic box and labels (if expected). |
CANOPEN1S | RS485 to CANOPEN interface, for DIN rail mounting. With UL marked PCB, Terminal block, plastic box and labels (if expected). |
191750 | Cable,Fieldbus option WE503 |
FB1SINST | Installation, configuration and testing of Fieldbus Module 1S. NET PRICE. |
Digital Input / Output | |
IOEXPB | Built-in board with 12 OUT and 6 IN (mounting and cable gland excluded). It includes expansion circuit of the power supply range of the indicator (8-40Vdc). NOT COMPATIBLE WITH 3590E4CH AND TPRXT. With UL marked PCB, Terminal block, plastic box and labels (if applicable). |
Analog Output | |
DAC16OSER | Built-in RS232 / RS485 optoisolated analog output, 0-4/20 mA, 0-10VDC . For DFW, 3590 Touch Screen. Output -10/+10VDC upon request, only at time of order. |
DAC16O-2 | Built-in optoisolated analog output, 0-4/20 mA, 0-10VDC (cable gland excluded). For DFW, 3590 and CPW indicators. Output -10/+10VDC upon request, only at time of order. NOTE: For 3590, IOEXPB option board is required, available depending on the model. |
ATEX 2GD Remote Button Control | |
EXPHBN | EX 2GD hand control with 2 buttons and cable gland (optional connection cable). Protection II 2G Ex db eb IIC T6 Gb for gases, II 2D Ex tb IIIC T80øC Db for dust. |
EXACB4 | 4x0.5 mmý armoured cable (suitable for Ex zones). PVC inner sheath. Armour: galvanised steel wire braid. Outer sheath PVC, diameter 7.3 mm. Temperature range: -30 / +80 øC. Minimum bending radius >/= 10 x O.D. _/m |
Printers/Labelers for safe zones | |
OBTPRB | Table thermal printer. For weight indicator, with IP40 ABS case, 1,5 m connection cable and internal power supply. Thermal paper roll included as standard. |
CODEPG | Service for loading a customised code-page on TPR printer (standard is PC437 - Central Europe, USA) |
LP542TE | Thermal transfer or direct thermal labelling machine Supplied with standard peel mechanism. Maximum printing size 25400 x 108 mm. Maximum roll O 127 mm and width up to 112 mm. Label roll and ribbon not included. |
SMTPLUS-1 | Thermal transfer or direct termal labeller. Peel-off kit in option. |
PRNSERV | Custom-made ticket (up to 4 layouts). NET price. |
APRNSERV | Custom-made label (up to 4 layouts). NET price. |
Connection cables | |
RSCBTW | 4-core twisted shielded cable (2x2x0.34 mmý), for RS485 communication or analogue output. Polyolefin inner sheath. Tinned copper braid shielding. Outer sheath PVC, diameter 7mm. Temperature range: -30 / +80 øC. Minimum bending radius >/= 6 x O.D. _/m |
ETHCBEX | Multi-core cable (4x2xAWG24) suitable for Ethernet connections in Ex-zones (connectors and cable gland only installed with S6 service). First shield: aluminium/polyester tape, second shield: tinned copper braid (coverage = 85% - EMC 89/336). Outer sheath: PVC, diameter 6.3mm. Temperature range: -30 / +80 øC. Minimum bending radius >/= 8 x O.D. Minimum length 10 m. _/m |
Columns and supports | |
STFI-1 | AISI 304 stainless steel fixing bracket. For weight indicator wall mounting. |
STFR-1 | AISI 304 stainless steel fixing bracket with adjustable inclination. For weight indicator wall mounting. |
STFA12 | Stainless steel bracket for mounting the ATEX battery on column. Compatible with "DFWBP76ATEX..", "IECEXB", "BP6ESTATEX3GD.." and "BP6V12A". |
PANEL-ST | Bracket for mounting the indicator on the panel. |
CSP38I-1 | AISI 304 stainless steel column 450x450mm, h=917mm, O 38mm. For the indicators of the DINI ARGEO and SCALE HOUSE range. |
Zener barriers for load cells | |
ZBA1S | Intrinsic protection three channel Zener barrier. Specific for connection to load cells, for mounting on DIN rail in a safe area, or in a flame-proof case. Marking: ATEX/IECEx II (1) GD [Ex ia Ga] IIC [Ex ia Da] IIIC. Manual and ATEX UE CONFORMITY DECLARATIONS (available in EN, DE, FR, ES and IT). |
ZBINST | Installation of the ZBA1S / PFB485EX zener barrier inside the indicator case. Note: The cable (LCCB for barrier ZBA1S, RSCBTW for barrier PFB485EX) of the desired length must also be purchased. NET PRICE. |
LCCB | Shielded cable 6x0.25 mmý (suitable for Ex zones). PVC inner sheath. Tinned copper braid shielding. PVC outer sheath, diameter 5.8 mm. Temperature range: -40 / +80 øC. Minimum bending radius >/= 6 x O.D. _/m |
PFB485EX | Protection barrier for RS485, for direct connection in safe area. Max cable length: 200m. |
RSCBTW | 4-core twisted shielded cable (2x2x0.34 mmý), for RS485 communication or analogue output. Polyolefin inner sheath. Tinned copper braid shielding. Outer sheath PVC, diameter 7mm. Temperature range: -30 / +80 øC. Minimum bending radius >/= 6 x O.D. _/m |
KMB4-1 | Kit of 3 ATEX Zener barriers for load cells, in an ABS box. For up to 4 load cells of 350 ohm, for intrinsic protection weighing systems in a dangerous area. Marking of the whole box with three Zener barriers: ATEX II 3(1)G Ex nA [ia Ga] IIC T4 Gc (-20øC = Ta = +40øC) for gas, ATEX II 3(1)D Ex tb [ia Da] IIIC T130øC Dc IP65 (-20øC = Ta = +40øC) for dusts. Provided with safety instructions and the ATEX EU declaration of conformity (EN and IT). |
KZBA-1 | ATEX ABS housing kit with Zener Barrier ZBA1S for load cells. For intrinsically safe weighing systems in a dangerous zone. Dimensions 179x359x166,5mm. It can connect up to 8 350 Ohm load cells. Marking of housing + Zener Barrier ZBA1S: ATEX II 3(1)G Ex nA [ia Ga] IIC T4 Gc X for gas, ATEX II 3(1)D Ex tc [ia Da] IIIC T135øC Dc IP66 X for dust. Provided with safety instructions and the ATEX EU declaration of conformity (EN and IT). |
PG Cable Glands | |
PG7EX | 10 PG7 metallic cable gland set for ATEX indicators. Complete with ferrules and seals. Cable diameter: 3 to 6.5 mm. |
PG9EX | 10 PG9 metallic cable gland set for ATEX indicators. Complete with ferrules and seals. Cable diameter: 4 to 8 mm. |
Other options | |
TECSUP | Technical assistance by telephone upon request. |
ECEMDOC | Printed EU declaration of conformity, EU certificate of verification, test certificate and metrological book (free download from our website, only for approved CE-M products). NET _. |