3590EGT-IECEX3GD Touchscreen Indicator for Ex 2 and 22 Zones
Standard Features
- IECEx certification.
- New enclosure with screwless front closure for easy cleaning of the indicator.
- PG7 and PG9 cable glands with adapters for 4 to 7 mm and 7 to 10 mm cable routing. Equipped with anti-friction system that does not require additional external cable fixing, as required by the IECEx scheme and ATEX directives.
- Available in specific version for direct connection to load cells installed in zone 1/21 and 0/20.
- 5,7' colour touch screen display.
- Multilanguage software.
- 15-key alphanumerical waterproof keyboard.
- 3-way control light.
- Selectable QWERTY, AZERTY or QWERTZ keyboard integrated in the touch screen.
- Stainless steel waterproof enclosure, with new IP68 protection system.
- Dimensions: 280x143x185mm.
- Suitable for use on the table.
- Real time clock and permanent data storage.
- Alibi memory as standard, integrated on the motherboard.
- Slot for built-in micro SD to record the configuration, logos, and customized screens (upon request).
- Functions available with DINITOOLS utility
- Configuration, data entry and print formatting.
- Recording and filing of all the information on PC.
- Complete retrieval of the configuration.
- Instrument calibration with numeric values.
- Customization of the screens. - 24-bit A/D converter, 4 channels, up to 3200 conv./sec. with automatic frequency selection and up to 8 signal linearisation points.
- 4 independent analogue channels for weight reading (up to 2 in E-AF03 version).
- Connection with up to 16 analogue load cells of 350 Ohm (45 load cells of 1000 Ohm).
- Up to 10.000e OIML or multi-range 3 x 3000e @ 0,3 µV/d CE-M legal for trade.
- Up to 1.000.000 displayable divisions for internal factory use, with internal resolution up to 3.000.000 points.
- Connectable to printers and labellers with free programming of the printout formats.
- Power supply from 110-240Vac line or 12-24 Vdc Max. 25.2W.
Weight Indicator for Hazardous Areas
Weight indicator with a big touch screen display, for ATEX 2 & 22 hazardous zones.
ATEX/IECEX marking:
- II 3G Ex nR IIC T6 Gc X (0°C<= Ta <=50°C) for gases
- II 3D Ex tc IIIC T85°C Dc IP65 X (0°C<= Ta <=50°C) for dust.
ATEX/IECEX marking with intrinsically safe connection for load cells:
- II 3G Ex nR [ia] IIC T6 Gc X (0°C<= Ta <=50°C) for gases.
- II 3D Ex tc [ia] IIIC T85°C Dc IP65 X (0°C<= Ta <=50°C) for dust.
Suitable for advanced industrial applications, it's fitted with 3 serial ports, Ethernet communication port, configurable printouts and integrated alibi memory.
CE-M approvable (OIML R-76 / EN 45501).
3590EGT-IECEX3GD Touch Screen Indicator for Ex 2 and 22 Zones Specifications
I/O SECTION:
|
COMPLETE PROGRAMMABLITY FOR CUSTOMISED APPLICATIONS:
Dini Argeo also offers the service of software development (to be quoted).
STANDARD APPLICATIONS:
|
MAIN CERTIFICATIONS:
AVAILABLE LANGUAGES:
|
Parts
Part # | Description |
---|---|
Available versions | |
3590EGT-IECEX3GD | Ex colour Touch Screen indicator for zone 2/22 with AF01 software. IP68 stainless steel enclosure. ATEX/IECEX II 3G Ex nR IIC T6 Gc X (0øC<= Ta <=50øC) for gas and II 3D Ex tc IIIC T85øC Dc IP65 X (0øC<= Ta <=50øC) for dust. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT). |
3590EGT-IECEX3GDZB | Ex colour Touch Screen indicator for zone 2/22 with AF01 software, connectable directly to load cells installed in zone 1/21 and 0/20. IP68 stainless steel enclosure. ATEX/IECEX marking: II 3G Ex nR [ia] IIC T6 Gc X (0øC<= Ta <=50øC) for gas and II 3D Ex tc [ia] IIIC T85øC Dc IP65 X (0øC<= Ta <=50øC) for dust. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT). |
Options
Part # | Description |
---|---|
Available firmwares | |
AF02 | Software for piece/quantity counting. |
AF03GT | Software for weighbridges, vehicle In/Out. For 3590 "TOUCH SCREEN" weight indicators. |
AF04GT | Software for statistical checking of prepackaged goods. For 3590 "TOUCH SCREEN" weight indicators. |
AF05 | Software for price computing and industrial labelling. |
AF08 | Software for static wheel and axle weighing with 2 or more pads. |
AF09 | Software for dynamic and static axle weighing with 1 or 2 pads. |
BATCH1 | Software for single product dosage systems in loading and unloading. |
BATCH | Software for multicomponent dosage systems in loading and unloading. NOTE: For 3590, IOEXPB expansion board is required. |
Optional power supply cords | |
EXACB4 | 4x0.5 mmý armoured cable (suitable for Ex zones). PVC inner sheath. Armour: galvanised steel wire braid. Outer sheath PVC, diameter 7.3 mm. Temperature range: -30 / +80 øC. Minimum bending radius >/= 10 x O.D. _/m |
Declaration of ATEX conformity | |
DCATEX3GD | Declaration of ATEX conformity of whole. Ex II 3G IIC T6 Gc X and Ex II 3D IIIC T115øC Dc X system, with relative label of whole system, for ATEX certified or NOT ATEX certified Dini Argeo indicator (in the latter case to be installed in a safe area) connected to a mechanical structure with ATEX load cells (each load cell must be certified with CCATEX or CCATEX3GD option). Provided with descriptive document of the assembly and ATEX EU declaration of conformity of the assembly (EN, DE, FR, ES and IT). |
DCATEXMB4 | ATEX declaration for the whole system with Dini Argeo Zener barriers. Ex II 2G IIC T6 Gb X e Ex II 2D IIIC T125øC Db X system, with label of the whole system, for weight indicator connected to Dini Argeo zener barriers, connected to a mechanical structure with ATEX load cells (each cell must be certified with CCATEX option). Provided with descriptive document of the assembly and ATEX EU declaration of conformity of the assembly (EN and IT). |
Approval for sale to third parties | |
KCEM | Plates and Welmec form for legal trade use of a scale. NET PRICE. Service available in combination with a Dini Argeo indicator. |
ECEMDOC | Printed EU declaration of conformity, EU certificate of verification, test certificate and metrological book (free download from our website, only for approved CE-M products). NET _. |
ECEM-AU | Single platform/scale legal-for-trade approval for Australia. |
Printers/Labelers for safe zones | |
OBTPRB | Table thermal printer. For weight indicator, with IP40 ABS case, 1,5 m connection cable and internal power supply. Thermal paper roll included as standard. |
CODEPG | Service for loading a customised code-page on TPR printer (standard is PC437 - Central Europe, USA) |
LP542TE | Thermal transfer or direct thermal labelling machine Supplied with standard peel mechanism. Maximum printing size 25400 x 108 mm. Maximum roll O 127 mm and width up to 112 mm. Label roll and ribbon not included. |
SMTPLUS-1 | Thermal transfer or direct termal labeller. Peel-off kit in option. |
SMTRPK-1 | Label peel-off and rewind kit for SMTPLUS-1 labeller. |
PRNSERV | Custom-made ticket (up to 4 layouts). NET price. |
APRNSERV | Custom-made label (up to 4 layouts). NET price. |
Connection cables | |
RSCBTW | 4-core twisted shielded cable (2x2x0.34 mmý), for RS485 communication or analogue output. Polyolefin inner sheath. Tinned copper braid shielding. Outer sheath PVC, diameter 7mm. Temperature range: -30 / +80 øC. Minimum bending radius >/= 6 x O.D. _/m |
ETHCBEX | Multi-core cable (4x2xAWG24) suitable for Ethernet connections in Ex-zones (connectors and cable gland only installed with S6 service). First shield: aluminium/polyester tape, second shield: tinned copper braid (coverage = 85% - EMC 89/336). Outer sheath: PVC, diameter 6.3mm. Temperature range: -30 / +80 øC. Minimum bending radius >/= 8 x O.D. Minimum length 10 m. _/m |
Support brackets | |
EXSTFR | AISI 304 stainless steel bracket, adjustable inclination. For mounting IECEX weight indicators on the wall. |
EXSTFI | AISI 304 stainless steel wall bracket. For mounting IECEX weight indicators. |
PANEL-ST | Bracket for mounting the indicator on the panel. |
Storing the weighs | |
SWM | "WeiMonitor" PC program to monitor and record in real time weighs performed on the connected scale (the price is intended for the license to manage one scale). |
Software for display customisation | |
DDT | Software for the quick customisation of the touchscreen display. For 3590ET and 3590EGT series indicators. |
Communication Interfaces | |
RF2G4 | Built-in 2.4 GHz radiofrequency module. Max. functioning distance in appropriate environmental and installation conditions: 45m indoors, 140m outdoors. Up to 39 configurable channels. (RF2G4 must be combined with another radio module). |
PROFI232-1 | External RS232/RS485/PROFIBUS interface for DIN bar. Connectable to the indicators with Profibus protocol with PCB, terminal blocks, plastic box and UL-marked labels (if applicable). |
BLTH-3 | Built-in bluetooth interface. For wireless connection of the scale to tablets, smartphones, laptops or barcode scanners. Attention: this interface is not suitable for Master-Slave systems. |
ETHD | Built-in Ethernet interface. Speed from 10 to 100 Mbps, TCP, UDP, IP, ARP, ICMP, Ethernet Mac protocols. |
Fieldbus interfaces | |
PROFINET1S | RS485 to ProfiNET interface, for DIN rail mounting. With UL marked PCB, Terminal block, plastic box and labels (if expected). |
ETHERNETIP1S | RS485 to Ethernet IP interface, for DIN rail mounting. With UL marked PCB, Terminal block, plastic box and labels (if expected). |
ETHERCAT1S | RS485 to EtherCAT interface, for DIN rail mounting. With UL marked PCB, Terminal block, plastic box and labels (if expected). |
DEVICENET1S | RS485 to DeviceNET interface, for DIN rail mounting. With UL marked PCB, Terminal block, plastic box and labels (if expected). |
CANOPEN1S | RS485 to CANOPEN interface, for DIN rail mounting. With UL marked PCB, Terminal block, plastic box and labels (if expected). |
191750 | Cable,Fieldbus option WE503 |
FB1SINST | Installation, configuration and testing of Fieldbus Module 1S. NET PRICE. |
Display customization | |
GTMEM | 10 memories set for display customization with logos and images. |
Digital Input / Output | |
IOEXPB | Built-in board with 12 OUT and 6 IN (mounting and cable gland excluded). It includes expansion circuit of the power supply range of the indicator (8-40Vdc). NOT COMPATIBLE WITH 3590E4CH AND TPRXT. With UL marked PCB, Terminal block, plastic box and labels (if applicable). |
Analog Ouput | |
DAC16OSER | Built-in RS232 / RS485 optoisolated analog output, 0-4/20 mA, 0-10VDC . For DFW, 3590 Touch Screen. Output -10/+10VDC upon request, only at time of order. |
DAC16O-2 | Built-in optoisolated analog output, 0-4/20 mA, 0-10VDC (cable gland excluded). For DFW, 3590 and CPW indicators. Output -10/+10VDC upon request, only at time of order. NOTE: For 3590, IOEXPB option board is required, available depending on the model. |
PG cable glands | |
PG7-IECEX | PG7 Cable Gland for DFW and 3590 IECEx Series Cable diameter: 4 to 7 mm. |
PG9-IECEX | PG9 Cable Gland for DFW and 3590 IECEx Series Complete with ferrules and seals. Cable diameter: 4 to 7 mm or 7 to 10 mm. |
PG13-IECEX | PG13 Cable Gland for DFW and 3590 IECEx Series Complete with ferrules and seals. Cable diameter: 5,5 to 8 mm, 8 to 10,5 mm or 10,5 to 13 mm. |
Other options | |
TECSUP | Technical assistance by telephone upon request. |