Is the website displaying in the correct language? Please confirm or select a different language.
Your region has been set to Italy. Please confirm or select a different region.
ATEX/IECEX Triple Zener Barrier for Load Cells ZBA1S
-
Three channels passive zener barrier for power supply, reference and signal. Ex marking: ATEX II (1)G, II (1)D, I (M1)IECEx [circuit(s) in zone 0/1/2]
-
Protection: [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I (-20 °C ≤ Tamb ≤ +60 °C)
- Equipped with 3 channels for the protection of the Signal line (CN1/CN4), the Excitation line (CN3/CN6) and the Sense line, for improved signal stability.
- “SLIM” type case, iper-compact, for DIN rail installation.
- Temperature of usage: -20°C ÷ +60°C.
- Storage temperature: -25°C ÷ +70°C
- Rating: 14Vrms differential and 8Vrms through earth for CN3 connector, 20Vrms for the CN1 & CN2
- Maximum Security Voltage(Um): 250Vrms
- Maximum Security Current (current interruption capability): 1500A
- Degree of protection: IP20
- Excitation, Signal and Sense Marking: ATEX II (1)G, II(1)D, I(M1)
- Protection: [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I (-20°C ≤ Tamb ≤ +60°C)
- NOTE:
- Can connect up to 4 Load Cell of 350 Ohm.
- Combined use of one or more Zener Barriers (1) GD [Ex ia], implies that the Atex marking of the set of barriers must be upgraded (2) GD [Ex ib], as written in the EN 60079-14 normative.
KZBA Case Features:
- Material: ABS
- Glands: n.4, ATEX certified.
- Protection for Case + Barrier:
for gas:
- ATEX II 3(1) Ex nAa [ia Ga] IIC T4 Gc (-20°C ≤ Ta ≤ +50°C)
for dust:
- ATEX II 3(1)D Ex tb [ia Da] IIIC T130°C Dc IP65 (-20°C ≤ Ta ≤ +50°C)
The Zener Barrier ZBA1S is the perfect solution for the connection between a weighing terminal and a weight receiver system in the ATEX ZONE. ZBA1S integrates three barriers in one, protecting the excitation line, signal and sense. This feature makes the installation easier, especially in small spaces. This saves time and money.
Resources / Downloads
Articles
Title | View | Category | Type | |
---|---|---|---|---|
All Around Dini Argeo Weighing Solutions for Logistics and Warehouses | Pallet Truck Scales|Pallet Scales|Pallet Weighers|Electric Pallet Truck Scales|Ex Pallet Truck Scales|Hygienic Pallet Truck Scales|Pallet Weighing|Weighing Forks|Hydraulic Weighing|Counting Scales|Bench Scales|Axle Weighing Scales|In-Motion Axle Scales|Dynamic Axle Weighing|Weighing Axle Platforms and Indicators|High Resolution Load Cells|Off Center Load Cells|Bending Beam Load Cells|Shear Beam Load Cells|Double Shear Beam Load Cells|Compression Load Cells|Tension Load Cells|Column Load Cells|Assembly Kit Load Cells|Ex Load Cells|Hygienic Load Cells | Articles | ||
How to Choose the Best Load Cell for Your Needs | All Load Cells | Articles |
Options
Available versions
Part # | Description | List Price | Cart / Quote | |
---|---|---|---|---|
ZBA1S | Intrinsic protection three channel Zener barrier. Specific for connection to load cells, for mounting on DIN rail in a safe area, or in a flame-proof case. Marking: ATEX/IECEx II (1) GD [Ex ia Ga] IIC [Ex ia Da] IIIC. Manual and ATEX UE CONFORMITY DECLARATIONS (available in EN, DE, FR, ES and IT). |
Consult |
||
KZBA-1 | ATEX ABS housing kit with Zener Barrier ZBA1S for load cells. For intrinsically safe weighing systems in a dangerous zone. Dimensions 179x359x166,5mm. It can connect up to 8 350 Ohm load cells. Marking of housing + Zener Barrier ZBA1S: ATEX II 3(1)G Ex nA [ia Ga] IIC T4 Gc X for gas, ATEX II 3(1)D Ex tc [ia Da] IIIC T135øC Dc IP66 X for dust. Provided with safety instructions and the ATEX EU declaration of conformity (EN and IT). |
Consult |