DFW ATEX2GD Weight Indicator for ATEX 1 & 21 Zones
Standard Features
- Waterproof 17-key numerical and functional keyboard.
- LCD display with 6 25-mm high contrast digits, clearly visible even in poor lighting conditions and with low temperatures, and with 6 LEDs for showing the active functions.
- IP68 Satin finish stainless steel case.
- Dimensions 264x174x115mm.
- Suitable for use on the table, or wall.
- Up to 10.000e or multirange 3 x 3000e @ 0,3 µV/e in CE-M approved version for legal for trade use.
- Up to 1.000.000 displayable divisions with internal resolution up to 3.000.000 points.
- Up to 8 signal linearization points with DINITOOLS (3 from keypad).
- A/D 24-bit sigma-delta conversion, up to 200 conv./sec. autoselect.
- Digital calibration and set-up from keyboard; Instrument management & configuration from PC with DINITOOLS.
- Power supply through external module: with optional battery pack; or with optional power adapter connectable to mains at 230 Vac or at 24 Vdc.
- Connection with up to 4 load cells having 350 Ohm input resistance.
Weight indicator for areas classified as hazardous with protection methods according to:
ATEX II 2(2)G Ex ib [ib Gb] IIC T4 Gb for gases, ATEX II 2(2)D Ex tb [ib Db] IIIC T197°C IP65 Db for dust.
Ideal for creating weighing systems, batching, and automation systems. EC-Type-Examination certificate according to Annex III (ATEX directive). CE-M approvable (OIML R-76 / EN 45501).
DFW ATEX2GD Weight Indicator for ATEX 1 & 21 Zones Specifications
I/O Section (Only with DFWATEX2GDIO Model):
|
Functions:
|
Main Certifications:
|
Parts
Part # | Description |
---|---|
Available versions | |
DFWATEX2GD-1 | IP68 stainless steel, ATEX 2GD indicator. 17-key keypad and LCD display. Protection mode: ATEX II 2(2)G Ex ib [ib Gb] IIC T4 Gb for gases and ATEX II 2(2)D Ex tb [ib Db] IIIC T197øC IP65 Db for dust. Complete with manual and DECLARATION OF CONFORMITY. To be combined always with the PW200XRDxxx series' power adapter or DFWBP76ATEX battery. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT). |
DFWATEX2GDIO-1 | IP68 stainless steel, ATEX 2GD indicator fitted with I/O section. 17-key keypad and LCD display. Protection mode: ATEX II 2(2)G Ex ib [ib Gb] IIC T4 Gb for gases and ATEX II 2(2)D Ex tb [ib Db] IIIC T197øC IP65 Db for dust. Complete with manual and DECLARATION OF CONFORMITY. To be combined always with the PW200XRDxxx series' power adapter. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT). |
Options
Part # | Description |
---|---|
Approval kit | |
KCEM | Plates and Welmec form for legal trade use of a scale. NET PRICE. Service available in combination with a Dini Argeo indicator. |
ECEMDOC | Printed EU declaration of conformity, EU certificate of verification, test certificate and metrological book (free download from our website, only for approved CE-M products). NET _. |
ECEM-AU | Single platform/scale legal-for-trade approval for Australia. |
Declaration of ATEX conformity of whole | |
DCATEX2GD | Declaration of ATEX conformity of the assembly. Ex II 2G IIC T4 Gb X and Ex II 2D IIIC T197øC Db X SYSTEM, with relative label of whole system, for Dini Argeo ATEX weight indicator connected a mechanical structure with ATEX load cells (each cell must be certified with CCATEX option). Provided with descriptive document of the assembly and ATEX EU declaration of conformity of the assembly (EN and IT). |
Power supply and INPUT/OUTPUT for DFWATEX2GD | |
PW200XRD24D-1 | ATEX power supplier with 24 Vdc input. 10,5 Vdc intrinsically safe output, complete of Exd case, with protection modes: ATEX II 2(2)G Ex d [ib Gb] IIC T4 Gb and ATEX II 2(2)D Ex tb [ib Db] IIIC T140øC Db. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT). |
PW200XRD24A | ATEX power supplier with 24 Vac input. 10,5 Vdc intrinsically safe output, complete of Exd case, with protection modes: ATEX II 2(2)G Ex d [ib Gb] IIC T4 Gb and ATEX II 2(2)D Ex tb [ib Db] IIIC T140øC Db. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT). |
PW200XRD115 | ATEX power supplier with 115 Vac input. 10,5 Vdc intrinsically safe output, complete of Exd case, with protection modes: ATEX II 2(2)G Ex d [ib Gb] IIC T4 Gb and ATEX II 2(2)D Ex tb [ib Db] IIIC T140øC Db. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT). |
PW200XRD230-1 | ATEX power supplier with 230 Vac input. 10,5 Vdc intrinsically safe output, complete of Exd case, with protection modes: ATEX II 2(2)G Ex d [ib Gb] IIC T4 Gb and ATEX II 2(2)D Ex tb [ib Db] IIIC T140øC Db. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT). |
PW200IO | Set of 2 ATEX cable glands for PW200XRDxxx. For the use of the INPUT/OUTPUT section on DFWATEX2GDIO or DFWATEX2GDF. |
PW200IO-1 | Set of 2 ATEX cable glands for PW200XRDxxx-1. For the use of the INPUT/OUTPUT section on DFWATEX2GDIO or DFWATEX2GDF. |
EXACBPW | Armoured 4x1mmý cable, for Ex systems. _/m |
ATEX battery and battery charger | |
DFWBP76ATEXD | Rechargeable ATEX battery, for 1 & 21 zones. If used with DFWATEX weight indicator this battery needs the BTCB2GD optional cable. |
BTCB2GD | Cable for DFWBP76ATEXD battery connection. |
DFWBPAL-2 | Battery charger for safe area, for DFWBP76ATEXD ATEX battery. |
STFA12 | Stainless steel bracket for mounting the ATEX battery on column. Compatible with "DFWBP76ATEX..", "IECEXB", "BP6ESTATEX3GD.." and "BP6V12A". |
ATEX 2GD Remote Button Control | |
EXPHBN | EX 2GD hand control with 2 buttons and cable gland (optional connection cable). Protection II 2G Ex db eb IIC T6 Gb for gases, II 2D Ex tb IIIC T80øC Db for dust. |
EXACB4 | 4x0.5 mmý armoured cable (suitable for Ex zones). PVC inner sheath. Armour: galvanised steel wire braid. Outer sheath PVC, diameter 7.3 mm. Temperature range: -30 / +80 øC. Minimum bending radius >/= 10 x O.D. _/m |
Communication interfaces | |
ALMEMATEX | Alibi memory for ATEX 2GD indicator (fiscal memory, max 120.000 weighs) for approved transmission of the weight to PC/PLC (to be used with DFWATEX2GDIO). |
DF485EX | ATEX RS485 port, for DFWATEX2GDF and DFWATEX2GDIO. |
Optical fibres and converter | |
CBFOPT | Synthetic optical fibre cable. _/m (min. 10m). Caution: requires one CNFOPT fibre optic connector set. |
FBDIN100 | Optical fibre/RS232 converter for DIN bar, for synthetic optical fibre. The maximum length is 100m (greater lenghts upon price estimate). For the connection with PC, PLC. |
Connection cables | |
EXACB4 | 4x0.5 mmý armoured cable (suitable for Ex zones). PVC inner sheath. Armour: galvanised steel wire braid. Outer sheath PVC, diameter 7.3 mm. Temperature range: -30 / +80 øC. Minimum bending radius >/= 10 x O.D. _/m |
EXACBPW | Armoured 4x1mmý cable, for Ex systems. _/m |
EXCB6 | Blue shielded cable 6x0.22 mmý, only for EX i (2GD) assemblies. PVC inner sheath. Tinned copper braid shielding. Polyurethane outer sheath, diameter 5.8 mm. Temperature range: -40 / +80 øC. Minimum bending radius >/= 7 x O.D. _/m |
LCCB | Shielded cable 6x0.25 mmý (suitable for Ex zones). PVC inner sheath. Tinned copper braid shielding. PVC outer sheath, diameter 5.8 mm. Temperature range: -40 / +80 øC. Minimum bending radius >/= 6 x O.D. _/m |
LCCBA | Armoured cable 6x0.25 mmý (suitable for Ex zones). PVC inner sheath, diameter 5mm. Iron-zinc alloy armour. Transparent PVC outer sheath, 8 mm diameter. Temperature range: -15 / +70 øC. Minimum bending radius >/= 5 x O.D. _/m |
RSCBTW | 4-core twisted shielded cable (2x2x0.34 mmý), for RS485 communication or analogue output. Polyolefin inner sheath. Tinned copper braid shielding. Outer sheath PVC, diameter 7mm. Temperature range: -30 / +80 øC. Minimum bending radius >/= 6 x O.D. _/m |
Analog Output | |
PFB485EX | Protection barrier for RS485, for direct connection in safe area. Max cable length: 200m. |
DGT1SAN | Weight transmitter on DIN bar, with 2 INPUT, 2 OUTPUT and analog output. Fitted with 5-key keypad and LED display. Multifunction weighing program. |
MSTSLV | Program for using the indicator as a repeater. It must be combined with the DFW and DGT weight indicators. |
191750 | Cable,Fieldbus option WE503 |
Repeater for ATEX zone | |
MSTSLV | Program for using the indicator as a repeater. It must be combined with the DFW and DGT weight indicators. |
RS485 barriers | |
PFB485EX | Protection barrier for RS485, for direct connection in safe area. Max cable length: 200m. |
ZBPWR24 | Power supply specific for ZB485 active barrier. |
ZB485 | RS485 active barrier. Mark: ATEX II (1) GD [EEx ia] IIC, I (M2) [EEx ia] I, II 3G Ex nA II T4, [Ex ia] IIC. 24Vdc power supply not included, we recommend the combination with ZBPWR24. |
Saving of the weighs | |
SWM | "WeiMonitor" PC program to monitor and record in real time weighs performed on the connected scale (the price is intended for the license to manage one scale). |
PC software for managing weighbridges | |
WEITRUCK-1 | PC software for vehicle weighing. Combinable with DFW, DGT and 3590 series' weight indicators. Databases for storing the customer, material, and vehicle data, management of the totals and programmable printouts. Requires an Alibi Memory. |
Columns and brackets | |
STFI-1 | AISI 304 stainless steel fixing bracket. For weight indicator wall mounting. |
STFA12 | Stainless steel bracket for mounting the ATEX battery on column. Compatible with "DFWBP76ATEX..", "IECEXB", "BP6ESTATEX3GD.." and "BP6V12A". |
STFR-1 | AISI 304 stainless steel fixing bracket with adjustable inclination. For weight indicator wall mounting. |
CSP38I-1 | AISI 304 stainless steel column 450x450mm, h=917mm, O 38mm. For the indicators of the DINI ARGEO and SCALE HOUSE range. |
CSP38D | Stainless steel column 350x350mm, h=750mm. Painted steel base. For the indicators of the DINI ARGEO and SCALE HOUSE range. |
PG cable glands | |
PG7EX | 10 PG7 metallic cable gland set for ATEX indicators. Complete with ferrules and seals. Cable diameter: 3 to 6.5 mm. |
PG9EX | 10 PG9 metallic cable gland set for ATEX indicators. Complete with ferrules and seals. Cable diameter: 4 to 8 mm. |
Other accessories | |
VENTX | ATEX Valve for regulating humidity and pressure inside the indicator. Advised for IP68 applications. |
TECSUP | Technical assistance by telephone upon request. |