DFW-IECEX3GD: IECEx Weight Indicator For Ex 2 & 22 Zones
Standard Features
- IECEx certification.
- New enclosure with screwless front closure for easy cleaning of the indicator.
- PG7 and PG9 cable glands with adapters for 4 to 7 mm and 7 to 10 mm cable routing. Equipped with anti-friction system that does not require additional external cable fixing, as required by the IECEx scheme and ATEX directives.
- Available in specific version for direct connection to load cells installed in zone 1/21 and 0/20.
- 17-key high thickness waterproof keyboard.
- LCD display with backlight as standard with 6 25 mm digits.
- Satin IP68 stainless steel enclosure.
- Suitable for use on the table.
- Dimensions: 280x143x185mm.
- Up to 10.000e or 3 x 3000e @ 0,3 µV/d OIML approved version and CE-M legal for trade.
- Up to 1.000.000 displayable divisions for internal factory use.
- Up to 8 signal linearisation points with DINITOOLS (3 from the keyboard).
- Internal resolution up to 3.000.000 points.
- 24-bit sigma-delta A/D converter, up to 200 conv./sec. with automatic frequency selection.
- Board protection case inside the box.
- Calibration and digital Set-Up from the keyboard.
- Instrument management and configuration from PC with DINITOOLS.
- 4 channels (for single weighing system).
- Power supply from 110-240Vac line or 12-24 Vdc Max. 25.2W (optional power cable).
- Connection with up to 8 load cells of 350 Ohm.
Weight indicator for Ex areas classified as hazardous. ATEX/IECEx marking:
- II 3G Ex nR IIC T6 Gc X (0°C<= Ta <=50°C) for gas
- II 3D Ex tc IIIC T85°C Dc IP65 X (0°C<= Ta <=50°C) for dust.
- ATEX/IECEx marking with intrinsically safe connection for load cells:
- II 3G Ex nR [ia] IIC T6 Gc X (0°C<= Ta <=50°C) for gas
- II 3D Ex tc [ia] IIIC T85°C Dc IP65 X (0°C<= Ta <=50°C) for dust.
- Suitable to realize weighing, dosing and automation systems. CE-M approvable (OIML R-76 / EN 45501).
DFW-IECEX3GD: IECEx Weight Indicator For Ex 2 & 22 Zones Specifications
I/O SECTION:
MAIN CERTIFICATIONS:
|
MASTER/REPEATER OPTION:
|
FUNCTIONS:
AVAILABLE LANGUAGES FOR PRINTING
|
Parts
Part # | Description |
---|---|
Available versions | |
DFW-IECEX3GD | Ex Indicator for Zone 2/22. Stainless steel enclosure, IP68 protection, 17-key keypad, backlit LCD display and internal power supply. ATEX/IECEX Marking: II 3G Ex nR IIC T6 Gc X (0øC<= Ta <=50øC) for gas and II 3D Ex tc IIIC T85øC Dc IP65 X (0øC<= Ta <=50øC) for dust. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT). |
DFW-IECEX3GDZB | Ex Indicator for zone 2/22 that can be directly connected to load cells installed in zone 1/21 and 0/20. Stainless steel enclosure, IP68 protection, 17-key keypad, backlit LCD display and internal power supply. ATEX/IECEX Marking: II 3G Ex nR [ia] IIC T6 Gc X (0øC<= Ta <=50øC) for gas and II 3D Ex tc [ia] IIIC T85øC Dc IP65 X (0øC<= Ta <=50øC) for dust. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT). |
Options
Part # | Description |
---|---|
Available versions | |
DFW-IECEX3GD | Ex Indicator for Zone 2/22. Stainless steel enclosure, IP68 protection, 17-key keypad, backlit LCD display and internal power supply. ATEX/IECEX Marking: II 3G Ex nR IIC T6 Gc X (0øC<= Ta <=50øC) for gas and II 3D Ex tc IIIC T85øC Dc IP65 X (0øC<= Ta <=50øC) for dust. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT). |
DFW-IECEX3GDZB | Ex Indicator for zone 2/22 that can be directly connected to load cells installed in zone 1/21 and 0/20. Stainless steel enclosure, IP68 protection, 17-key keypad, backlit LCD display and internal power supply. ATEX/IECEX Marking: II 3G Ex nR [ia] IIC T6 Gc X (0øC<= Ta <=50øC) for gas and II 3D Ex tc [ia] IIIC T85øC Dc IP65 X (0øC<= Ta <=50øC) for dust. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT). |
Optional power supply cords | |
EXACB4 | 4x0.5 mmý armoured cable (suitable for Ex zones). PVC inner sheath. Armour: galvanised steel wire braid. Outer sheath PVC, diameter 7.3 mm. Temperature range: -30 / +80 øC. Minimum bending radius >/= 10 x O.D. _/m |
Declaration of ATEX conformity | |
DCATEX3GD | Declaration of ATEX conformity of whole. Ex II 3G IIC T6 Gc X and Ex II 3D IIIC T115øC Dc X system, with relative label of whole system, for ATEX certified or NOT ATEX certified Dini Argeo indicator (in the latter case to be installed in a safe area) connected to a mechanical structure with ATEX load cells (each load cell must be certified with CCATEX or CCATEX3GD option). Provided with descriptive document of the assembly and ATEX EU declaration of conformity of the assembly (EN, DE, FR, ES and IT). |
DCATEXMB4 | ATEX declaration for the whole system with Dini Argeo Zener barriers. Ex II 2G IIC T6 Gb X e Ex II 2D IIIC T125øC Db X system, with label of the whole system, for weight indicator connected to Dini Argeo zener barriers, connected to a mechanical structure with ATEX load cells (each cell must be certified with CCATEX option). Provided with descriptive document of the assembly and ATEX EU declaration of conformity of the assembly (EN and IT). |
Approval for sale to third parties | |
KCEM | Plates and Welmec form for legal trade use of a scale. NET PRICE. Service available in combination with a Dini Argeo indicator. |
ECEMDOC | Printed EU declaration of conformity, EU certificate of verification, test certificate and metrological book (free download from our website, only for approved CE-M products). NET _. |
ECEM-AU | Single platform/scale legal-for-trade approval for Australia. |
Date&Time option | |
DFCLK | Real time clock for printing/displaying of date and time. With UL marked PCB, screw terminal, plastic box and labels (if applicable). |
Communication Interfaces | |
ETHD | Built-in Ethernet interface. Speed from 10 to 100 Mbps, TCP, UDP, IP, ARP, ICMP, Ethernet Mac protocols. |
ALMEM-1 | Alibi memory (fiscal memory, max 120.000 weighs) for approved weight transmission to PC/PLC or data recording on MMC/USB. Built-in real time clock to print the date/time with PCB, screw terminal, plastic box and UL-marked labels (if applicable). |
RS485C | Built-in RS485 interface (mounting and cable gland excluded). |
Digital Input / Output | |
DFIO3GD-1 | ATEX 3GD built-in 2 IN/6 OUT interface (requires FW 05.05.00 or higher). |
Printers/Labelers for safe zones | |
OBTPRB | Table thermal printer. For weight indicator, with IP40 ABS case, 1,5 m connection cable and internal power supply. Thermal paper roll included as standard. |
CODEPG | Service for loading a customised code-page on TPR printer (standard is PC437 - Central Europe, USA) |
LP542TE | Thermal transfer or direct thermal labelling machine Supplied with standard peel mechanism. Maximum printing size 25400 x 108 mm. Maximum roll O 127 mm and width up to 112 mm. Label roll and ribbon not included. |
Connection cables | |
RSCBTW | 4-core twisted shielded cable (2x2x0.34 mmý), for RS485 communication or analogue output. Polyolefin inner sheath. Tinned copper braid shielding. Outer sheath PVC, diameter 7mm. Temperature range: -30 / +80 øC. Minimum bending radius >/= 6 x O.D. _/m |
ETHCBEX | Multi-core cable (4x2xAWG24) suitable for Ethernet connections in Ex-zones (connectors and cable gland only installed with S6 service). First shield: aluminium/polyester tape, second shield: tinned copper braid (coverage = 85% - EMC 89/336). Outer sheath: PVC, diameter 6.3mm. Temperature range: -30 / +80 øC. Minimum bending radius >/= 8 x O.D. Minimum length 10 m. _/m |
Support brackets | |
EXSTFR | AISI 304 stainless steel bracket, adjustable inclination. For mounting IECEX weight indicators on the wall. |
EXSTFI | AISI 304 stainless steel wall bracket. For mounting IECEX weight indicators. |
PANEL-ST | Bracket for mounting the indicator on the panel. |
Weight repeater software | |
MSTSLV | Program for using the indicator as a repeater. It must be combined with the DFW and DGT weight indicators. |
PC software for managing weighbridges | |
WEITRUCK-1 | PC software for vehicle weighing. Combinable with DFW, DGT and 3590 series' weight indicators. Databases for storing the customer, material, and vehicle data, management of the totals and programmable printouts. Requires an Alibi Memory. |
Storing the weighs | |
SWM | "WeiMonitor" PC program to monitor and record in real time weighs performed on the connected scale (the price is intended for the license to manage one scale). |
PG cable glands | |
PG7-IECEX | PG7 Cable Gland for DFW and 3590 IECEx Series Cable diameter: 4 to 7 mm. |
PG9-IECEX | PG9 Cable Gland for DFW and 3590 IECEx Series Complete with ferrules and seals. Cable diameter: 4 to 7 mm or 7 to 10 mm. |
PG13-IECEX | PG13 Cable Gland for DFW and 3590 IECEx Series Complete with ferrules and seals. Cable diameter: 5,5 to 8 mm, 8 to 10,5 mm or 10,5 to 13 mm. |
Other options | |
TECSUP | Technical assistance by telephone upon request. |