DFWKXT: IP68 Multifunction Weight Indicators
Standard Features
- 17-key numerical and functional waterproof keypad.
- 25mm LCD backlit display with 6 high contrast digits with icons indicating the active functions.
- Easy to clean STAINLESS STEEL waterproof IP68 enclosure built to withstand harsh washdown and corrosive environments.
- Suitable for use on the table, column, or wall.
- Dimensions: 264x174x115mm.
- 24-bit A/D converter, 4 channels, up to 200 conv./sec. and up to 8 signal linearisation points.
- Up to 10.000e or multirange 3 x 3000e @ 0,3 µV/e in CE-M approved version for legal for trade use.
- Up to 1.000.000 displayable divisions with internal resolution up to 3.000.000 points.
- Digital calibration and set-up through keyboard or PC with DINITOOLS.
- Built-in rechargeable battery (60 hours with one 350-Ohm load cell) and power supply 110-240 Vac.
- Connectable with up to 8 350-Ohm load cells or up to 16 700-Ohm load cells.
High performance and versatile weighing indicators. A wide range of application programmes and interfaces make these suitable for many industrial and commercial weighing applications such as platform scales, mobile weighing, etc. CE-M approvable (OIML R-76 / EN 45501).
"DFWKXT": IP68 MULTIFUNCTION WEIGHT INDICATORS Specifications
I/O Section
Main Certifications
|
Master/Repeater Option
|
Functions
|
Parts
Part # | Description |
---|---|
Available versions | |
DFWKXTBC-1 | 17-key indicator with IP68 stainless steel case. Backlit LCD display, and standard weighing programme. |
Options
Part # | Description |
---|---|
Optional power supply cords | |
PWCORDUK | Power supply cord with BS1363 plug (UK plug). |
PWCORDCH | Power supply cord with SEV1011 plug (CH plug). |
PWCORDUS | Version with US type B power cord (Japan, North and Central America). |
PWCORDAUS | Version with AU power cord. |
Available firmwares | |
DFWPK | Program for detecting weight peaks or kg to N conversion |
Junction Box / Boards - Load Cell cables | |
DFW4CH | Internal board for a quick connection of more (equalised) channels. |
LCCBC | Cable for connection between platform and indicator, l=50cm. Female connector to be soldered. |
LCCB5C | LCCBC cable + 5m extension cable. |
LCCB10C | LCCBC cable + 10m extension cable. |
Approval for sale to third parties | |
KCEM | Plates and Welmec form for legal trade use of a scale. NET PRICE. Service available in combination with a Dini Argeo indicator. |
ECEM | 3000e legal for trade approval, for single platform/scale. NOTE: Depending on the product, the ECEM approval service may require DINICAL calibration service. Check to see if DINICAL is in the product options. |
ECEM-AU | Single platform/scale legal-for-trade approval for Australia. |
Storing the weighs | |
SWM | "WeiMonitor" PC program to monitor and record in real time weighs performed on the connected scale (the price is intended for the license to manage one scale). |
USBC-1 | Built-in USB port kit for data storing on USB key. Fitted with USB key for PC. |
USBK | Set of 5 USB keys for recording the weighs. |
PC software for managing weighbridges | |
WEITRUCK-1 | PC software for vehicle weighing. Combinable with DFW, DGT and 3590 series' weight indicators. Databases for storing the customer, material, and vehicle data, management of the totals and programmable printouts. Requires an Alibi Memory. |
Printers/Labelers | |
TPRXT | Attached stainless steel IP65 thermal printer. NOTE: incompatible with IOEXPB board. Thermal paper roll included as standard. |
LP542TE | Thermal transfer or direct thermal labelling machine Supplied with standard peel mechanism. Maximum printing size 25400 x 108 mm. Maximum roll O 127 mm and width up to 112 mm. Label roll and ribbon not included. |
SMTPLUS-1 | Thermal transfer or direct termal labeller. Peel-off kit in option. |
RSCBLP | RS232 cable l=1,5m for LP542xx, SMTPLUS, PR80 printers. |
RSCBLP10M | RS232 cable l=10m for LP542xx, SMTPLUS, PR80 printers. |
CNFSERV | Custom-made printouts for DFW and DFWL series. NET price. |
CODEPG | Service for loading a customised code-page on TPR printer (standard is PC437 - Central Europe, USA) |
Communication Interfaces | |
RSCBUSB485 | USB cable converter PC/RS485, l=1,5m. With metallic PG9 cable gland. To be combined with an indicator fitted with optional or standard RS485 output. |
OBRF2G4 | External 2.4 GHz radio module, cable l=3m. ABS IP65 protecting box, 3 m cable, power supply from weight indicator. Max. distance, in appropriate environmental and installation conditions: 45 m indoors, 140m outdoors. 39 configurable channels. |
OBRF2G4-USB | External 2.4 GHz radio frequency module, USB cable l=1m. Power supply directly from the USB port. Max. functioning distance, in appropriate environmental and installation conditions: 45 m indoors, 140 outdoors. 39 configurable channels. |
BLTH-3 | Built-in bluetooth interface. For wireless connection of the scale to tablets, smartphones, laptops or barcode scanners. Attention: this interface is not suitable for Master-Slave systems. |
ALMEM-1 | Alibi memory (fiscal memory, max 120.000 weighs) for approved weight transmission to PC/PLC or data recording on MMC/USB. Built-in real time clock to print the date/time with PCB, screw terminal, plastic box and UL-marked labels (if applicable). |
ETHD | Built-in Ethernet interface. Speed from 10 to 100 Mbps, TCP, UDP, IP, ARP, ICMP, Ethernet Mac protocols. |
WIFITPWLK-1 | Built-in WI-FI interface. For wireless connection (through access point) to the company computer system. |
DFIO-1 | Built-in 2 IN / 6 OUT interface (requires FW 05.05.00 or higher). |
DAC16O-2 | Built-in optoisolated analog output, 0-4/20 mA, 0-10VDC (cable gland excluded). For DFW, 3590 and CPW indicators. Output -10/+10VDC upon request, only at time of order. NOTE: For 3590, IOEXPB option board is required, available depending on the model. |
DF485 | RS485 bidirectional port for DFW series. |
Connection cables | |
RSCBRJ | RS232/C serial cable - DB9/RJ11 - l=1,5m. |
RSCBRJ10M | RS232/C serial cable - DB9/RJ11 - l=10m. |
RSCBUSBPG | USB PC/RS232 converter cable, l=1,5m, with PG9. USB/RJ11 connector. For the connection to weight indicators with IP65 and IP68 protection system. |
ETHCBRJ | Ethernet cable, l=1,5m. Fitted with fairlead, for connection between indicator and PC network. |
Date&Time option | |
DFCLK | Real time clock for printing/displaying of date and time. With UL marked PCB, screw terminal, plastic box and labels (if applicable). |
Control light | |
OBCLTI | Stainless steel 3 way control light (for indic. with relais output). For attached mounting to the stainless steel indicators of the "XT" line. Connection cable and power supply from indicator. |
Weight repeater software | |
MSTSLV | Program for using the indicator as a repeater. It must be combined with the DFW and DGT weight indicators. |
Weight repeaters | |
DGT100R-1 | Weight repeater with 100mm LED display. IP68 stainless steel case, 5-key keypad, air valve for regulating the humidity and the pressure. |
Columns, supports brackets, visors | |
STFI-1 | AISI 304 stainless steel fixing bracket. For weight indicator wall mounting. |
STFR-1 | AISI 304 stainless steel fixing bracket with adjustable inclination. For weight indicator wall mounting. |
CSP38I-1 | AISI 304 stainless steel column 450x450mm, h=917mm, O 38mm. For the indicators of the DINI ARGEO and SCALE HOUSE range. |
CSP38 | Stainless steel column 450x450mm, h=917, O 38mm. Painted steel base. For the indicators of the DINI ARGEO and SCALE HOUSE range. |
CSP38D | Stainless steel column 350x350mm, h=750mm. Painted steel base. For the indicators of the DINI ARGEO and SCALE HOUSE range. |
Options for ATEX version | |
ZBA1S | Intrinsic protection three channel Zener barrier. Specific for connection to load cells, for mounting on DIN rail in a safe area, or in a flame-proof case. Marking: ATEX/IECEx II (1) GD [Ex ia Ga] IIC [Ex ia Da] IIIC. Manual and ATEX UE CONFORMITY DECLARATIONS (available in EN, DE, FR, ES and IT). |
KZBA-1 | ATEX ABS housing kit with Zener Barrier ZBA1S for load cells. For intrinsically safe weighing systems in a dangerous zone. Dimensions 179x359x166,5mm. It can connect up to 8 350 Ohm load cells. Marking of housing + Zener Barrier ZBA1S: ATEX II 3(1)G Ex nA [ia Ga] IIC T4 Gc X for gas, ATEX II 3(1)D Ex tc [ia Da] IIIC T135øC Dc IP66 X for dust. Provided with safety instructions and the ATEX EU declaration of conformity (EN and IT). |
PFB485EX | Protection barrier for RS485, for direct connection in safe area. Max cable length: 200m. |
DCATEXMB4 | ATEX declaration for the whole system with Dini Argeo Zener barriers. Ex II 2G IIC T6 Gb X e Ex II 2D IIIC T125øC Db X system, with label of the whole system, for weight indicator connected to Dini Argeo zener barriers, connected to a mechanical structure with ATEX load cells (each cell must be certified with CCATEX option). Provided with descriptive document of the assembly and ATEX EU declaration of conformity of the assembly (EN and IT). |
KMB4-1 | Kit of 3 ATEX Zener barriers for load cells, in an ABS box. For up to 4 load cells of 350 ohm, for intrinsic protection weighing systems in a dangerous area. Marking of the whole box with three Zener barriers: ATEX II 3(1)G Ex nA [ia Ga] IIC T4 Gc (-20øC = Ta = +40øC) for gas, ATEX II 3(1)D Ex tb [ia Da] IIIC T130øC Dc IP65 (-20øC = Ta = +40øC) for dusts. Provided with safety instructions and the ATEX EU declaration of conformity (EN and IT). |
JB4QA | ATEX equalisation box made of ABS IP67, for up to 4 cells. 4 + 1 fairleads. Marking: ATEX II 2G Ex ib IIC T6 Gb for gases, ATEX II 2D Ex tb IIIC T115øC Db IP65 for dust. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT). |
JB4QAI | ATEX equalisation box made of stainless steel IP66 for up to 4 cells. 4 + 1 fairleads. Marking: ATEX II 2G Ex ib IIC T6 Gb for gases, ATEX II 2D Ex tb IIIC T115øC Db IP65 for dusts. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT). |
EXCB6 | Blue shielded cable 6x0.22 mmý, only for EX i (2GD) assemblies. PVC inner sheath. Tinned copper braid shielding. Polyurethane outer sheath, diameter 5.8 mm. Temperature range: -40 / +80 øC. Minimum bending radius >/= 7 x O.D. _/m |
Remote control | |
TLRP | Radio frequency remote control and receiver with extension, for installations where other option boards with connection to AMP are required. |
PG cable glands | |
PG7M | 10 PG7 metallic cable gland set for weight indicators. |
PG9M | 10 PG9 metallic cable gland set for weight indicators. |
PG9PG11C | Kit of 10 metalic IP68 from PG9 to PG11 adapters (o max cable 12mm) |
PG9PG13C | Kit of 10 metalic IP68 from PG9 to PG13 adapters (o max cable 12mm) |
Options only available at time of order | |
TECSUP | Technical assistance by telephone upon request. |
TECMAN | Printed technical manual (Free download from the website). |
UMAN | Printed user manual (Free download from the website). |
ECEMDOC | Printed EU declaration of conformity, EU certificate of verification, test certificate and metrological book (free download from our website, only for approved CE-M products). NET _. |