DGT1S PLUS: Multifunction Digital Weight Transmitter
Standard Features
Compact multifunction weight transmitter, for DIN rail mounting. It allows the direct reading and diagnostics of the connected weighing system. The wide range of available interfaces makes the integration of the weighing in any automation system easier and safer.
Available versions
PROFINET | ETHERNET/IP | MODBUS/TCP | ETHERCAT | PROFIBUS | DEVICENET | CANOPEN | ANALOG OUTPUT | RS485
Approvals
CE-M EN 45501, OIML R-76, OIML R-61 (MID), OIML R-51 (MID)
On board Web Server
Integrated WebServer as standard, for configuration, diagnostics and data backup.
Specifications
Number of scales/channels: Calibration:
Conversion rate: Maximum number of load cells: Minimum sensitivity:
Number of legal-for-trade divisions: Load cell excitation voltage: Communication ports:
Communication protocols:
|
Communication rate:
PC programs for configuration: Display: Keyboard: Housing: Power supply: Operating temperature range: Max. humidity: |
INPUTS/OUTPUTS:
CERTIFICATIONS:
|
Parts
Part # | Description |
---|---|
Available Versions | |
DGT1SP | Weight transmitter on DIN rail, with 2 INPUTS and 4 OUTPUTS. Fitted with 5-key keypad and LED display. Multifunction weighing program. |
DGT1SP-AN | Weight transmitter on DIN rail, with 2 INPUT, 4 OUTPUT and analog output. Fitted with 5-key keypad and LED display. Multifunction weighing program. |
DGT1SP-PRONET | Weight transmitter on DIN rail, with 2 IN, 4 OUT and PROFINET port. Fitted with 5-key keypad and LED display. Multifunction weighing program. |
DGT1SP-ETHIP | Weight transmitter on DIN rail, with 2 IN, 4 OUT and EtherNet/IP port. EtherNet/IP. Fitted with 5-key keypad and LED display. Multifunction weighing program. |
DGT1SP-MODTCP | Weight transmitter on DIN rail, with 2 IN, 4 OUT and Modbus/TCP port. Fitted with 5-key keypad and LED display. Multifunction weighing program. |
DGT1SP-ETHCAT | Weight transmitter on DIN rail, with 2 IN, 4 OUT and EtherCAT port. Fitted with 5-key keypad and LED display. Multifunction weighing program. |
DGT1SP-PB | Weight transmitter on DIN rail, with 2 IN, 4 OUT and Profibus port. Fitted with 5-key keypad and LED display. Multifunction weighing program. |
DGT1SP-DEVNET | Weight transmitter on DIN rail, with 2 IN, 4 OUT and DeviceNet port. Fitted with 5-key keypad and LED display. Multifunction weighing program. |
Options
Part # | Description |
---|---|
RS485 lightning and surge protection | |
RS485PDIN | Protection circuit for port 485, with enclosure for DIN rail installation. Protection according to IEC 1000-4-5/D (IEC 801-5/D). |
Approval for sale to third parties | |
KCEM | Plates and Welmec form for legal trade use of a scale. NET PRICE. Service available in combination with a Dini Argeo indicator. |
ECEM-AU | Single platform/scale legal-for-trade approval for Australia. |
Clock Calendar / Alibi Memory for type-approved communication | |
ALMEM3V3-1 | Alibi memory (fiscal memory, max 120.000 weighs) for approved weight transmission to PC/PLC or data recording on MMC/USB. Built-in real time clock to print the date/time with PCB, screw terminal, plastic box (it requires FW 05.00.02 or higher). |
DFCLK3V3-1 | Real time clock for printing/displaying of date and time. . |
PC Softwares | |
D-LEGAL | Legal for trade approved software for recording weighing results to a PC (virtual alibi function) with an integrated API library for interfacing with other software. |
D-API | Software for recording weighing results to a PC (for internal use) with an integrated API library for interfacing with other software. |
Power supplier for DIN bar | |
MDR2012 | 12Vdc power unit for DIN bar. 110/240Vac input. CE and UL certified. Not compatible with BOX2121S. |
Communication Interfaces | |
SETHDIN-1 | RS232 / RS485 / Ethernet converter. Modbus RTU / Modbus TCP/IP (if applicable). Connectable to all Dini Argeo weight indicators via the serial port. ABS housing for DIN rail. With PCB, screw terminals, plastic box and UL marked labels (if applicable). |
Options for ATEX version | |
ZBA1S | Intrinsic protection three channel Zener barrier. Specific for connection to load cells, for mounting on DIN rail in a safe area, or in a flame-proof case. Marking: ATEX/IECEx II (1) GD [Ex ia Ga] IIC [Ex ia Da] IIIC. Manual and ATEX UE CONFORMITY DECLARATIONS (available in EN, DE, FR, ES and IT). |
KZBA-1 | ATEX ABS housing kit with Zener Barrier ZBA1S for load cells. For intrinsically safe weighing systems in a dangerous zone. Dimensions 179x359x166,5mm. It can connect up to 8 350 Ohm load cells. Marking of housing + Zener Barrier ZBA1S: ATEX II 3(1)G Ex nA [ia Ga] IIC T4 Gc X for gas, ATEX II 3(1)D Ex tc [ia Da] IIIC T135øC Dc IP66 X for dust. Provided with safety instructions and the ATEX EU declaration of conformity (EN and IT). |
KMB4-1 | Kit of 3 ATEX Zener barriers for load cells, in an ABS box. For up to 4 load cells of 350 ohm, for intrinsic protection weighing systems in a dangerous area. Marking of the whole box with three Zener barriers: ATEX II 3(1)G Ex nA [ia Ga] IIC T4 Gc (-20øC = Ta = +40øC) for gas, ATEX II 3(1)D Ex tb [ia Da] IIIC T130øC Dc IP65 (-20øC = Ta = +40øC) for dusts. Provided with safety instructions and the ATEX EU declaration of conformity (EN and IT). |
DCATEXMB4 | ATEX declaration for the whole system with Dini Argeo Zener barriers. Ex II 2G IIC T6 Gb X e Ex II 2D IIIC T125øC Db X system, with label of the whole system, for weight indicator connected to Dini Argeo zener barriers, connected to a mechanical structure with ATEX load cells (each cell must be certified with CCATEX option). Provided with descriptive document of the assembly and ATEX EU declaration of conformity of the assembly (EN and IT). |
JB4QA | ATEX equalisation box made of ABS IP67, for up to 4 cells. 4 + 1 fairleads. Marking: ATEX II 2G Ex ib IIC T6 Gb for gases, ATEX II 2D Ex tb IIIC T115øC Db IP65 for dust. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT). |
JB4QAI | ATEX equalisation box made of stainless steel IP66 for up to 4 cells. 4 + 1 fairleads. Marking: ATEX II 2G Ex ib IIC T6 Gb for gases, ATEX II 2D Ex tb IIIC T115øC Db IP65 for dusts. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT). |
EXCB6 | Blue shielded cable 6x0.22 mmý, only for EX i (2GD) assemblies. PVC inner sheath. Tinned copper braid shielding. Polyurethane outer sheath, diameter 5.8 mm. Temperature range: -40 / +80 øC. Minimum bending radius >/= 7 x O.D. _/m |
Other accessories / options | |
UMAN | Printed user manual (Free download from the website). |
TECMAN | Printed technical manual (Free download from the website). |
TECSUP | Technical assistance by telephone upon request. |
ECEMDOC | Printed EU declaration of conformity, EU certificate of verification, test certificate and metrological book (free download from our website, only for approved CE-M products). NET _. |