DSBI Series Double Shear Beam Stainless Steel Load Cell
Standard Features
- C4 Precision Class
- 17-4 PH Stainless Steel Construction
- IP68 Protection
- Max. capacities from 10,000 TO 30,000 kg
- Shielded connection cable
- Test certificate available upon request
CAPACITIES (kg): 10000, 20000, 30000.
OIML R60. C4 precision class.
17-4 PH stainless steel. IP68 protection.
Stainless steel double shear beam load cells suitable for building, for example, to make CE-M approved scales for high capacities or for weighing tanks and hoppers with the relevant accessories. High accuracy also with the expansion of the weighing structures.
DSBI Series Specifications
Minimum load cell verification interval: Combined error: Full Scale Output: Temperature effect on zero: Temperature effect on full scale output: Compensated Temperature Range: |
Operating Temperature Range: Creep error after 30 minutes: Maximum tolerated excitation voltage: Input Resistance: Output Resistance: |
Zero Balance: Insulation Resistance: Safe Overload: Ultimate Overload: Shielded cable: |
Wiring Code
Wiring Code | |
Colour | Function |
GREEN | OUTPUT + |
PURPLE | SENSE + |
RED | INPUT + |
WHITE | OUTPUT - |
BLACK | INPUT - |
GREY | SENSE - |
ATEX Version
- The CCATEX certificate makes the load cell suitable for use in hazardous areas with protection methods according to:
ATEX II 1G Ex ia IIC T6 (Ta -20÷+40°C) TX (Ta -20÷+65°C) Ga
ATEX II 1D Ex ta IIIC TX°C (Ta -20÷+40°C) TX°C (Ta -20÷+65°C) Da IP65.
The certificate includes the manual and the ATEX CE conformity declaration (available in EN, DE, FR, and IT). - IMPORTANT: the certificate refers to the single load cell. For systems with more load cells, it is necessary to order one certificate for each load cell.
DSBI Series Dimensions
Code | Max (kg) |
l |
w (mm) |
h (mm) |
a (mm) |
bØ (mm) |
c Ø (mm) |
d (mm) |
DSBI10 | 10.000 | 170 | 49.2 | 49.2 | 142 | N°2 x 20 | 25.4 | 12.7 |
DSBI20 | 20.000 | 170 | 49.2 | 49.2 | 142 | N°2 x 20 | 25.4 | 12.7 |
DSBI30 | 30.000 | 170 | 49.2 | 49.2 | 142 | N°2 x 20 | 25.4 | 12.7 |
Parts
Part # | Description |
---|---|
Available Versions | |
DSBI10 | Double shear beam approved load cell, C4, Max=10000kg. Stainless steel, IP68 protection degree. |
DSBI20 | Double shear beam approved load cell, C4, Max=20000kg. Stainless steel, IP68 protection degree. |
DSBI30 | Double shear beam approved load cell, C4, Max=30000kg. Stainless steel, IP68 protection degree. |
Options
Part # | Description |
---|---|
Assembly kits | |
KDSBN | Stainless steel kit for assembling 1 DSBI cell up to 30000kg. (Load cell not included) |
Options for ATEX version | |
ZBA1S | Intrinsic protection three channel Zener barrier. Specific for connection to load cells, for mounting on DIN rail in a safe area, or in a flame-proof case. Marking: ATEX/IECEx II (1) GD [Ex ia Ga] IIC [Ex ia Da] IIIC. Manual and ATEX UE CONFORMITY DECLARATIONS (available in EN, DE, FR, ES and IT). |
KZBA-1 | ATEX ABS housing kit with Zener Barrier ZBA1S for load cells. For intrinsically safe weighing systems in a dangerous zone. Dimensions 179x359x166,5mm. It can connect up to 8 350 Ohm load cells. Marking of housing + Zener Barrier ZBA1S: ATEX II 3(1)G Ex nA [ia Ga] IIC T4 Gc X for gas, ATEX II 3(1)D Ex tc [ia Da] IIIC T135øC Dc IP66 X for dust. Provided with safety instructions and the ATEX EU declaration of conformity (EN and IT). |
JB4QAI | ATEX equalisation box made of stainless steel IP66 for up to 4 cells. 4 + 1 fairleads. Marking: ATEX II 2G Ex ib IIC T6 Gb for gases, ATEX II 2D Ex tb IIIC T115øC Db IP65 for dusts. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT). |
JB4QA | ATEX equalisation box made of ABS IP67, for up to 4 cells. 4 + 1 fairleads. Marking: ATEX II 2G Ex ib IIC T6 Gb for gases, ATEX II 2D Ex tb IIIC T115øC Db IP65 for dust. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT). |
LCCB | Shielded cable 6x0.25 mmý (suitable for Ex zones). PVC inner sheath. Tinned copper braid shielding. PVC outer sheath, diameter 5.8 mm. Temperature range: -40 / +80 øC. Minimum bending radius >/= 6 x O.D. _/m |
LCCBA | Armoured cable 6x0.25 mmý (suitable for Ex zones). PVC inner sheath, diameter 5mm. Iron-zinc alloy armour. Transparent PVC outer sheath, 8 mm diameter. Temperature range: -15 / +70 øC. Minimum bending radius >/= 5 x O.D. _/m |
EXCB6 | Blue shielded cable 6x0.22 mmý, only for EX i (2GD) assemblies. PVC inner sheath. Tinned copper braid shielding. Polyurethane outer sheath, diameter 5.8 mm. Temperature range: -40 / +80 øC. Minimum bending radius >/= 7 x O.D. _/m |
KMB4-1 | Kit of 3 ATEX Zener barriers for load cells, in an ABS box. For up to 4 load cells of 350 ohm, for intrinsic protection weighing systems in a dangerous area. Marking of the whole box with three Zener barriers: ATEX II 3(1)G Ex nA [ia Ga] IIC T4 Gc (-20øC = Ta = +40øC) for gas, ATEX II 3(1)D Ex tb [ia Da] IIIC T130øC Dc IP65 (-20øC = Ta = +40øC) for dusts. Provided with safety instructions and the ATEX EU declaration of conformity (EN and IT). |
CCATEX-1 | Optional ATEX version for single load cell. Marking: ATEX II 1G Ex ia IIC T6 (Ta -20ö+40øC) TX (Ta -20ö+65øC) Ga and ATEX II 1D Ex ta IIIC TXøC (Ta -20ö+40øC) TXøC (Ta -20ö+65øC) Da IP65. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT). |
CCATEX3GD | ATEX certificate for each load cell. Marking: ATEX II 3G Ex nA IIC T6 Gc for gas and ATEX II 3D Ex tc IIIC T115øC Dc IP65 for dusts. Complete with manual and ATEX CE conformity declaration (available in EN, DE, FR and IT). |
DCATEXMECH | ATEX version for the PLATFORM / LOAD CELL MOUNTING KIT for zone 1/21 (for the load cells ATEX declaration see CCATEX code). Option to be offered only if the platform is ordered without the indicator, otherwise refer to the available certifications for the chosen weight indicator. Provided with safety instructions and ATEX EU declaration of conformity (EN, DE, FR, ES and IT). |
DCATEXMB4 | ATEX declaration for the whole system with Dini Argeo Zener barriers. Ex II 2G IIC T6 Gb X e Ex II 2D IIIC T125øC Db X system, with label of the whole system, for weight indicator connected to Dini Argeo zener barriers, connected to a mechanical structure with ATEX load cells (each cell must be certified with CCATEX option). Provided with descriptive document of the assembly and ATEX EU declaration of conformity of the assembly (EN and IT). |