Multi-Product Dosage Functioning

Standard Features
DATABASES
- Database of 16 selectable products/phases which may be:
- Automatic dosage;
- Manual dosage, with possibility of managing a control light;
- Complete or partial unloading;
- Fractioned unloading, for dividing all the dosed material in equal quantities;
- Timer, for enabling mixers, burners, or stirrers for a preestablished time period;
- Pause, for allowing the manual operations of the operator;
- Manual weight, for adding pre-weighed quantities to the dosage. - Database of 15 formulas, each one can contain:
- up to 8 products/phases with target, speed change threshold, flight, +/- tolerance;
- minimum tare and maximum tare values.
FUNCTIONING OF THE DOSAGE IN UNLOADING
- 1. Once the dosage start command is received, the instrument:
- verifies that the quantity of material is sufficient to execute the programmed dosage cycle and that the weight is stable,
- executes the automatic tare and the enabling of the automation through its dedicated outputs: the dosages start at maximum speed. - 2. Once the speed switch threshold is reached, the dosage slows down through its dedicated output.
- 3. When the TARGET is reached and the configured flight weight is missing, it disables the dosage output, and then it waits (for the configured time) for dropping the material.
- 4. Tolerance test on the dosed weight.
- 5. Storage of the formula consumptions and increment of the dosed general total.
- 6. Waits for the start of the new dosage or automatically restarts with the following cycle.
Configuration which allows the dosage of various products, in loading or unloading, as well as mixing and formulation, with the possibility of managing mixers, burners or vibrators using dedicated contacts.
Specifications
I/O FUNCTIONS:
|
DOSAGE FUNCTIONS: Selectable dosage mode between automatic or guided manual. Checking of the tare presence at the dosage start; the tare values are programmable for each formula. Automatic printing of the dosage data. Storage and printing of the consumptions. Printouts may be quickly recalled from the keyboard. Automatic correction of the flight weight. Repetitions of the programmable dosage cycles; infinite cycle function. Tolerance test on the dosed weight, with guided correction on display. Check of the maximum dosage time. Alarms indication on display. |
KEBOARD FUNCTIONS:
|
Options
Part # | Description |
---|---|
{#Available indicators in multi-product dosage version} | |
DGTQF | Microcontroller for dosage, with 2 IN and 6 OUT. 5-key keypad and LED display. |
DGTQFAN | Microcontroller for dosage, with 2 IN, 6 OUT, analogue output. 5-key keypad and LED display. |
DGTPF | Microcontroller for dosage with 4 IN and 6 OUT. 5-key keypad and LED display. |
DGTPFAN | Microcontroller for dosage with 4 IN, 6 OUT and analogue output. 5-key keypad and LED display. |
DGTPKFV2 | Indicator for dosage, with 4 IN and 6 OUT. Stainless steel case for table or panel mounting, 20-key keypad and LED display. |
DGTPKFANV2 | Indicator for dosage, with 4 IN, 6 OUT, analog output. Stainless steel case for table or panel mounting, 20-key keypad, LED display, and standard weighing program. |
DFWATEX2GDF | ATEX 2GD indicator for single and multi product dosage. IP68 stainless stell case, 17-key keypad and LCD display. Protection mode: ATEX II 2(2)G Ex ib [ib Gb] IIC T4 Gb for gases and ATEX II 2(2)D Ex tb [ib Db] IIIC T197°C IP65 Db for dust. To be combined always with the PW200XRDxxx series' power adapter and PW200IO option. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT). |