RL5426 Plus Series, Rice Lake Canister Load Cell, in Stainless Steel
Standard Features
Canister load cells for CE-M approved weighbridges, tanks, silos, etc. Manufactured in STAINLESS STEEL, IP69K protection degree, 6000 divisions.
CAPACITIES: 20 t, 30 t, 40t, 50 t.
OIML R60. C6 precision class.
Stainless steel body. IP69K Protection Degree.
20 m armoured rat-proof cable with stainless steel armouring as standard.
h= 118,5 mm.
RL5426 Series Specifications
Rated capacity (FS): Combined error: Creep error (after 30 min.): Temperature effect on zero: Temperature effect on sensitivity: Non-linearity error: Non-repeatability error: 0,006%F.S.
|
Gas dischargers to protect against atmospheric discharges Power Supply: Rated output at F.S.: Input resistance: Output resistance: Insulation resistance: Operating temperature: Compensated temperature for homologation: Storage temperature limits: |
Normal service: Maximum load / Safe load: Ultimate overload: IP69K protection degree Stainless steel body 6-core cable with stainless steel shield, length 20 m, diameter 6mm Nickel plated steel cable gland with protective spring Self-centring spherical bases Equipped with anti-rotation system, to be combined with 173798 cups for proper operation WARNING: |
Connection
Cable Color Code | |
---|---|
RED |
INPUT +
|
BLACK |
INPUT -
|
GREEN |
OUTPUT +
|
WHITE |
OUTPUT -
|
YELLOW |
SENSE +
|
BLUE |
SENSE -
|
METAL |
Shield
|
Installation Kit
- The 173798 kit allows a correct installation of the RL5426 load cells below the weighbridge plate.
- The kit consists of an upper cup and a lower cup with anti-rotation system. All components are made from stainless steel. Both cups are designed for optimal operation in conjunction with the cell’s self-centring spherical bases, allowing their proper oscillation and return to position.
Parts
Part # | Description |
---|---|
Available versions | |
RL5426-20T | RL5426 Canister load cell, C6 approved, Max=20t. |
RL5426-30T | RL5426 Canister load cell, C6 approved, Max=30t. |
RL5426-40T | RL5426 Canister load cell, C6 approved, Max= 40t. |
RL5426-50t | RL5426 Canister load cell, C6 approved, Max=50t. |
Assembly kits | |
173798 | Cup Set RL5426-01 Stainless Steel Cup Set for RL5426 Load Cells |
173801 | Tank Mount,RL5426-04N Nickel Plated Tank Mount for RL5426 Load Cells |
Options
Part # | Description |
---|---|
Junction Box / Boards - Cell cables | |
JB10Q | Equalisation box for connection with up to 10 analogue load cells. Reinforced polyester box, with 10 + 1 cable glands. With surge arresters, PCB, Terminal block, plastic box and UL marked labels (if applicable). |
LCCB | Shielded cable 6x0.25 mmý (suitable for Ex zones). PVC inner sheath. Tinned copper braid shielding. PVC outer sheath, diameter 5.8 mm. Temperature range: -40 / +80 øC. Minimum bending radius >/= 6 x O.D. _/m |
LCCBA | Armoured cable 6x0.25 mmý (suitable for Ex zones). PVC inner sheath, diameter 5mm. Iron-zinc alloy armour. Transparent PVC outer sheath, 8 mm diameter. Temperature range: -15 / +70 øC. Minimum bending radius >/= 5 x O.D. _/m |
Protection for junction box/electronic circuits | |
GELBOX | Anti condensation, insulating, and sealing gel. Useful for the protection of the electronic circuits of the weighing system, even in conditions of prolonged immersions in time. Pack of 300ml. |