SPBC Series Off-Center Load Cells
Standard Features
- C3 precision class
- Off center load compensated
- Made in aluminium alloy
- IP65 protection
- capacities from 100 to 630kg
- For platforms with dimensions up to 700 x 700 mm
- Shielded connection cable
- OIML certificate available upon request
- Test certificate available upon request
CAPACITIES (kg): 100, 200, 300, 500, 630.
OIML R60. C3 precision class.
Aluminium alloy. IP65 protection.
Load cells for off center loads, suitable for example to build CE-M approved scales with a single load cell with maximum dimensions of 700x700 mm.
Specifications
Minimum load cell verification interval: Maximum number of verification intervals: Full Scale Output: Combined error: Temperature effect on zero: Temperature effect on full scale output: |
Compensated Temperature Range: Operating Temperature Range: Creep error after 30 minutes: Maximum tolerated excitation voltage: Input Resistance: Output Resistance: |
Zero Balance: Insulation Resistance: Safe Overload: Ultimate Overload: Nominal displacement: Shielded cable: |
Wiring Code
SPBC Wiring Code
|
|
Colour |
Function
|
-- |
SHIELD
|
YELLOW |
OUTPUT +
|
GREY |
SENSE +
|
BROWN |
INPUT +
|
WHITE |
OUTPUT -
|
GREEN |
INPUT -
|
PINK |
SENSE -
|
ATEX Version
The CCATEX certificate makes the load cell suitable for use in hazardous areas with protection methods according to:
ATEX II 1G Ex ia IIC T6 (Ta -20÷+40°C) TX (Ta -20÷+65°C) Ga
ATEX II 1D Ex ta IIIC TX°C (Ta -20÷+40°C) TX°C (Ta -20÷+65°C) Da IP65.
The certificate includes the manual and the ATEX CE conformity declaration (available in EN, DE, FR, and IT).
IMPORTANT: the certificate refers to the single load cell. For systems with more load cells, it is necessary to order one certificate for each load cell.
Dimensions
Code | Max (kg) |
Plate Max (mm) |
l (mm) |
w (mm) |
h (mm) |
a |
b (mm) |
c Ø (mm) |
d (mm) |
e (mm) |
f (mm) |
g (mm) |
SPBC100 | 100 | 700 x 700 | 190 | 73 | 47 | 25 | 60 | N°8 x M8 | 40 | 15 | 7,5 | 6,5 |
SPBC200 | 200 | 700 x 700 | 190 | 73 | 47 | 25 | 60 | N°8 x M8 | 40 | 15 | 7,5 | 6,5 |
SPBC300 | 300 | 700 x 700 | 190 | 73 | 47 | 25 | 60 | N°8 x M8 | 40 | 15 | 7,5 | 6,5 |
SPBC500 | 500 | 700 x 700 | 190 | 73 | 47 | 25 | 60 | N°8 x M8 | 40 | 15 | 7,5 | 6,5 |
SPBC630 | 630 | 700 x 700 | 190 | 73 | 47 | 25 | 60 | N°8 x M8 | 40 | 15 | 7,5 | 6,5 |
Parts
Part # | Description |
---|---|
Available Versions | |
SPBC100 | Single point approved load cell in aluminium alloy, IP65 protection degree, 100 kg capacity, C3 precision class, 350 Ohm output resistance. |
SPBC200 | Single point approved load cell, C3, Max=200kg. Aluminium alloy, IP65 protection degree, 350 Ohm output resistance. |
SPBC300 | Single point approved load cell, C3, Max=300kg. Aluminium alloy, IP65 protection degree, 350 Ohm output resistance. |
SPBC500 | Single point approved load cell in aluminium alloy, IP65 protection degree, 500 kg capacity, C3 precision class, 350 Ohm output resistance. |
SPBC630 | Single point approved load cell, C3, Max=630kg. Aluminium alloy, IP65 protection degree, 350 Ohm output resistance. |
Options
Part # | Description |
---|---|
Options for ATEX version | |
LCCB | Shielded cable 6x0.25 mmý (suitable for Ex zones). PVC inner sheath. Tinned copper braid shielding. PVC outer sheath, diameter 5.8 mm. Temperature range: -40 / +80 øC. Minimum bending radius >/= 6 x O.D. _/m |
LCCBA | Armoured cable 6x0.25 mmý (suitable for Ex zones). PVC inner sheath, diameter 5mm. Iron-zinc alloy armour. Transparent PVC outer sheath, 8 mm diameter. Temperature range: -15 / +70 øC. Minimum bending radius >/= 5 x O.D. _/m |
EXCB6 | Blue shielded cable 6x0.22 mmý, only for EX i (2GD) assemblies. PVC inner sheath. Tinned copper braid shielding. Polyurethane outer sheath, diameter 5.8 mm. Temperature range: -40 / +80 øC. Minimum bending radius >/= 7 x O.D. _/m |
CCATEX-1 | Optional ATEX version for single load cell. Marking: ATEX II 1G Ex ia IIC T6 (Ta -20ö+40øC) TX (Ta -20ö+65øC) Ga and ATEX II 1D Ex ta IIIC TXøC (Ta -20ö+40øC) TXøC (Ta -20ö+65øC) Da IP65. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT). |
CCATEX3GD | ATEX certificate for each load cell. Marking: ATEX II 3G Ex nA IIC T6 Gc for gas and ATEX II 3D Ex tc IIIC T115øC Dc IP65 for dusts. Complete with manual and ATEX CE conformity declaration (available in EN, DE, FR and IT). |