T C6 Series Single-Cell Platforms
Standard Features
- Functions with a C6 6000e approved aluminium “single point” load cell according to OIML R60 standards with protection against dust and water splashes according to IP67 standards (350 Ohm input resistance).
- Steel tubular structure, oven-fire painted blue, with adjustable resting feet and level.
- Fitted with AISI 304 satin finish stainless steel loading surface.
- Up to 15 Vdc power supply.
- Shielded 3m connection cable with connectors (IP65) for connection to the indicator.
- Special sizes and capacities (upon estimate).
Painted Steel. Load cell in Aluminium. IP67 protection rating.
Precision class C3MI, C6, C6MR.
Small and medium capacity electronic platforms with a AISI304 stainless steel surface.
- Up to 30000d resolution.
- OIML R60 C6.
- IP67 protection.
Specifications
Multi Interval Version "-MI" The T and TE series scales are available in a 2x3000e multi-range approved version, the best combination of accuracy and ease of use for a class C3 approved weighing instrument. Compared to the more common multi-range type approval, the multi-interval type approval offers ADAPTIVE measurement resolution, which automatically varies by adjusting to the weight being measured. NOTE: Multi-interval models are distinguished by the final "-MI" abbreviation and must be paired with a DFW or 3590 series Dini Argeo indicator, DiniCal calibration service and ECEM2MI approval service. |
Options for ATEX Version CCATEX: ATEX certificate for each load cell. DCATEX2GD: Declaration of ATEX conformity of whole PLATFORM + ATEX 2GD DINI ARGEO INDICATOR. DCATEX3GD: Declaration of ATEX conformity of whole PLATFORM + ATEX 3GD DINI ARGEO INDICATOR. |
Available Upon Price Estimate Belt and roller units to be applied on the loading Surface. Special sizes and capacities. |
Available Versions
Code | l x w x h (mm) | Max (kg) | d (g) | M (g*) | d HR (g)* |
---|---|---|---|---|---|
TS3C6 | 230x330x93 | 3 | 0,5 | See table below | 0,1 |
TS3C6-MI | 230x330x93 | 3 | -- | 0,5/1 (Multi interval) | -- |
TS6C6 | 230x330x93 | 6 | 1 | See table below | 0,2 |
TS6C6-MI | 230x330x93 | 6 | -- | 1/2 (Multi interval) | -- |
TS12C6 | 230x330x93 | 12 | 2 | See table below | 0,5 |
TS12C6-MI | 230x330x93 | 12 | -- | 2/5 (Multi interval) | -- |
TT6C6 | 330x330x93 | 6 | 1 | See table below | 0,2 |
TT6C6-MI | 330x330x93 | 6 | -- | 1/2 (Multi interval) | - |
TT12C6 | 330x330x93 | 12 | 2 | See table below | 0,5 |
TT12C6-MI | 330x330x93 | 12 | -- | 2/5 (Multi interval) | -- |
TT30C6 | 330x330x93 | 30 | 5 | See table below | 1 |
TT30C6-MI | 330x330x93 | 30 | -- | 5/10 (Multi interval) | -- |
TQ12C6 | 400x400x115 | 12 | 5 | See table below | -- |
TQ12C6-MI | 400x400x115 | 12 | -- | 2/5 (Multi interval) | -- |
TQ30C6 | 400x400x115 | 30 | 5 | See table below | 1 |
TQ30C6-MI | 400x400x115 | 30 | -- | 5/10 (Multi interval) | -- |
TQ60C6 | 400x400x115 | 60 | 10 | See table below | 2 |
TQ60C6-MI | 400x400x115 | 60 | -- | 10/20 (Multi interval) | -- |
(*) Divisions obtainable only with the relative options, in combination with Dini Argeo weight indicator.
Multi-interval Versions
C3 | C6 | |||||
---|---|---|---|---|---|---|
ECEM2 MI 2x3000e |
ECEM-C6 6000e |
ECEM2-C6 6000+6000e |
||||
Max (kg) | e (g) | Max (kg) | e (g) | Max (kg) | e (g) | |
TS 230x330x90mm |
3 | 0,5/1 | 3 | 0,5 | -- | -- |
6 | 1/2 | 6 | 1 | 3/6 | 0,5/1 | |
12 | 2/5 | -- | -- | -- | -- | |
-- | -- | 12 | 2 | 6/12 | 1/2 | |
TT 330x330x90mm |
6 | 1/2 | 6 | 1 | 3/6 | 0,5/1 |
12 | 2/5 | -- | -- | -- | -- | |
-- | -- | 12 | 2 | 6/12 | 1/2 | |
30 | 5/10 | 30 | 5 | 12/30 | 2/5 | |
TQ |
12 | 2/5 | -- | -- | -- | -- |
-- | -- | 12 | 2 | 6/12 | 1/2 | |
30 | 5/10 | 30 | 5 | 12/30 | 2/5 | |
60 | 10/20 | 60 | 10 | 30/60 | 5/10 |
Parts
Part # | Description |
---|---|
Available Versions | |
TS3C6 | Platform made of painted steel, IP67, Max=3kg, d=0,5g, 230x330mm loading surface made of AISI304 stainless steel. 3m shielded cable. Aluminium load cell in C6 class. Optional calibration and approval services. |
TS6C6 | Platform made of painted steel, IP67, Max=6kg, d=1g, 230x330mm loading surface made of AISI304 stainless steel. 3m shielded cable. Aluminium load cell in C6 class. Optional calibration and approval services. |
TS12C6 | Platform made of painted steel, IP67, Max=12kg, d=2g, 230x330mm loading surface made of AISI304 stainless steel. 3m shielded cable. Aluminium load cell in C6 class. Optional calibration and approval services. |
TT6C6 | Platform made of painted steel, IP67, Max=6kg, d=1g, 330x330mm loading surface made of AISI304 stainless steel. 3m shielded cable. Aluminium load cell in C6 class. Optional calibration and approval services. |
TT12C6 | Platform made of painted steel, IP67, Max=12kg, d=2g, 330x330mm loading surface made of AISI304 stainless steel. 3m shielded cable. Aluminium load cell in C6 class. Optional calibration and approval services. |
TT30C6 | Platform made of painted steel, IP67, Max=30kg, d=5g, 330x330mm loading surface made of AISI304 stainless steel. 3m shielded cable. Aluminium load cell in C6 class. Optional calibration and approval services. |
TQ30C6 | Platform made of painted steel, IP67, Max=30kg, d=5g, 400x400mm loading surface made of AISI304 stainless steel. 3m shielded cable. Aluminium load cell in C6 class. Optional calibration and approval services. |
TQ60C6 | Platform made of painted steel, IP67, Max=60kg, d=10g, 400x400mm loading surface made of AISI304 stainless steel. 3m shielded cable. Aluminium load cell in C6 class. Optional calibration and approval services. |
Options
Part # | Description |
---|---|
Calibration service with weight indicator | |
DINICAL | Connection to a Dini Argeo indicator and calibration. NET PRICE (*). |
DINICAL-DRC | Connection to a Dini Argeo indicator and calibration. NET PRICE. |
Legal for trade approval , class III or IIII, with Dini Argeo indicator (only at time of order) | |
ECEM-C6 | 6000e legal for trade approval, for single platform/scale. NOTE: Depending on the product, the ECEM approval service may require DINICAL calibration service. Check to see if DINICAL is in the product options. |
ECEM2-C6 | Multi-range 6000+6000e legal for trade approval, for single platform/scale. NOTE: Depending on the product, the ECEM approval service may require DINICAL calibration service. Check to see if DINICAL is in the product options. |
ECEM2MI | Multi-interval 2x3000e legal for trade approval, for single platform/scale in xxx-MI version. NOTE: Depending on the product, the ECEM approval service may require DINICAL calibration service. Check to see if DINICAL is in the product options. |
ECEMDOC | Printed EU declaration of conformity, EU certificate of verification, test certificate and metrological book (free download from our website, only for approved CE-M products). NET _. |
HR calibration (high resolution) with Dini Argeo indicator (only at time of order) | |
THR | High Resolution (HR) model. |
Connection cables | |
JB1I | IP68 stainless steel single-channel junction box for 4-wire load cell cables. |
JB1AI | Stainless steel IP66, ATEX, juntion box for up to 1 cell. 1 + 1 fairleads. Protection modes: ATEX II 2G Ex ib IIC T6 Gb for gases, ATEX II 2D Ex tb IIIC T115øC Db IP65 for dusts. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT). |
LCCB | Shielded cable 6x0.25 mmý (suitable for Ex zones). PVC inner sheath. Tinned copper braid shielding. PVC outer sheath, diameter 5.8 mm. Temperature range: -40 / +80 øC. Minimum bending radius >/= 6 x O.D. _/m |
LCCBA | Armoured cable 6x0.25 mmý (suitable for Ex zones). PVC inner sheath, diameter 5mm. Iron-zinc alloy armour. Transparent PVC outer sheath, 8 mm diameter. Temperature range: -15 / +70 øC. Minimum bending radius >/= 5 x O.D. _/m |
Options for ATEX version (only at time of order) | |
CCATEX-1 | Optional ATEX version for single load cell. Marking: ATEX II 1G Ex ia IIC T6 (Ta -20ö+40øC) TX (Ta -20ö+65øC) Ga and ATEX II 1D Ex ta IIIC TXøC (Ta -20ö+40øC) TXøC (Ta -20ö+65øC) Da IP65. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT). |
CCATEX3GD | ATEX certificate for each load cell. Marking: ATEX II 3G Ex nA IIC T6 Gc for gas and ATEX II 3D Ex tc IIIC T115øC Dc IP65 for dusts. Complete with manual and ATEX CE conformity declaration (available in EN, DE, FR and IT). |
DCATEXMECH | ATEX version for the PLATFORM / LOAD CELL MOUNTING KIT for zone 1/21 (for the load cells ATEX declaration see CCATEX code). Option to be offered only if the platform is ordered without the indicator, otherwise refer to the available certifications for the chosen weight indicator. Provided with safety instructions and ATEX EU declaration of conformity (EN, DE, FR, ES and IT). |
IP68 protection | |
TIP68 | IP68 connection fitted with specific cable, fairleads and connectors. |
Columns, supports brackets, visors | |
TCBI350-1 | Stainless steel column h=350mm with stainless steel fixings. Fitted with bracket for DFW, DFWL, DFWLI, 3590E, 3590EGT, TRI, DGT20 and DGTPK series weight indicators. NOTE: on the TS and TT platforms it's possible to mount only DFWL, DFWLI, TRI, DGT20 and DGTPK. |
TCBI500-1 | Stainless steel column h=500mm with stainless steel fixings. Fitted with bracket for DFW, DFWL, DFWLI, 3590E, 3590EGT, TRI, DGT20, DGTPK series weight indicators (not compatible with TS and TT platforms). |
TCBI700-1 | Stainless steel column h=700mm with stainless steel fixings. Fitted with bracket for DFW, DFWL, DFWLI, 3590E, 3590EGT, TRI, DGT20, DGTPK series weight indicators (not compatible with TS and TT platforms). |
CSP38I-1 | AISI 304 stainless steel column 450x450mm, h=917mm, O 38mm. For the indicators of the DINI ARGEO and SCALE HOUSE range. |
CSP38 | Stainless steel column 450x450mm, h=917, O 38mm. Painted steel base. For the indicators of the DINI ARGEO and SCALE HOUSE range. |
CSP38D | Stainless steel column 350x350mm, h=750mm. Painted steel base. For the indicators of the DINI ARGEO and SCALE HOUSE range. |
PBSTF | Stainless steel fixing bracket for mounting the DFWL indicator. |
PBISTF | Stainless steel fixing bracket for mounting the DFWLI indicator. |
Charts for mobile weighing applications | |
TB60R2 | Painted steel cart, with low table top, for 400x400 or 400x500mm platform. Height of loading platform: 240mm. Only for T/TE, T C6, TE C6 and TE-69K series platforms. |
TB60EXR2 | Cart for ATEX zones, painted steel, with low loading platform, for 400x400 or 400x500mm platform. Height of loading surface: 235mm. Only for T/TE, T C6, TE C6 and TE-69K series platforms. Marking: ATEX II 2 G Ex h IIC T6 Gb (Ta -20øC ö +60øC) X for gas and ATEX II 2 D Ex h IIIC T85øC Db (Ta -20øC ö +60øC) X for dust. |
TB60BR2 | Painted steel cart, with low loading platform, for 500x500mm platform. Height of loading platform: 240mm. Only for T/TE, T C6, TE C6 and TE-69K series platforms. |
TB60BEXR2 | Cart for ATEX zones, painted steel, with low tablet top, for 500x500mm platform. Height of loading surface: 240mm. Only for T/TE, T C6, TE C6 and TE-69K series platforms. Marking: ATEX II 2 G Ex h IIC T6 Gb (Ta -20øC ö +60øC) X for gas and ATEX II 2 D Ex h IIIC T85øC Db (Ta -20øC ö +60øC) X for dust. |
TB300R2 | Painted steel cart, with low table top, for 500x600 or 600x600mm platforms. Height of loading platform: 260mm. Only for T/TE, T C6, TE C6 and TE-69K series platforms. |
TB300EXR2 | Cart for ATEX zones, painted steel, with low table top, for 500x600 or 600x600mm platform. Height of loading surface: 260mm. Only for T/TE, T C6, TE C6 and TE-69K series platforms. Marking: ATEX II 2 G Ex h IIC T6 Gb (Ta -20øC ö +60øC) X for gas and ATEX II 2 D Ex h IIIC T85øC Db (Ta -20øC ö +60øC) X for dust. |
TA60R2 | Cart for 400x400 or 400x500mm platform. Surface h=645mm. In painted steel. Only for T/TE, T C6 and TE C6 series platforms. |
TA60EXR2 | Cart for ATEX zones, painted steel, with high table top, for 400x400 mm or 400x500 mm platform. Height of loading surface: 640 mm. Only for T/TE, T C6, TE C6 and TE-69K series platforms. Marking: ATEX II 2 G Ex h IIB T6 Gb (Ta -20øC ö +60øC) X for gas and ATEX II 2 D Ex h IIIC T85øC Db (Ta -20øC ö +60øC) X for dust. |
TA300R2 | Painted steel cart, with high table top, for 500x600 or 600x600mm platform. Height of loading platform: 650mm. Only for T/TE, T C6, TE C6 and TE-69K series platforms. |
TA300EXR2 | Cart for ATEX zones, made of painted steel, with high table top, for 500x600 mm or 600x600 mm platform. Height of loading surface: 650 mm. Only for T/TE, T C6, TE C6 and TE-69K series platforms. Marking: ATEX II 2 G Ex h IIB T6 Gb (Ta -20øC ö +60øC) X for gas and ATEX II 2 D Ex h IIIC T85øC Db (Ta -20øC ö +60øC) X for dust. |
TKDC3 | Painted steel cart for double platform systems (TS/TT model on the high supporting surface and TQ/TM/TL/TX model on the low supporting surface), fitted with shelf for printer / labeller. |
TPBEI | Stainless steel plate AISI 304 for scale or labeller support for TA or TB carts. It can only be ordered in combination with TA and TB series carts. |
Raising Frame | |
SGAQR2 | Painted steel frame for 400x400mm platform. Loading surface h=605mm. |
SGAXR2 | Painted steel frame for 600x600mm platform. Loading surface h=600mm. |
Calibration service with Dini Argeo indicator (only at time of order) | |
CT3 | ISO 17025 calibration certificate up to 5 kg for single scale/platform. For precision and industrial scales, crane scales. The certificate is provided in digital format (pdf) and sent by e-mail. |
CT4 | ISO 17025 calibration certificate from 6 to 60 kg for single scale/platform. For precision and industrial scales, crane scales. The certificate is provided in digital format (pdf) and sent by e-mail. |
CT5 | ISO 17025 calibration certificate from 61 to 300 kg for single scale/platform. For precision and industrial scales, crane scales. The certificate is provided in digital format (pdf) and sent by e-mail. |
CT6 | ISO 17025 calibration certificate from 301 to 1500 kg for single scale/platform. For precision and industrial scales, crane scales. The certificate is provided in digital format (pdf) and sent by e-mail. |