Is the website displaying in the correct language? Please confirm or select a different language.
Your region has been set to Italy. Please confirm or select a different region.
TE 69K Series Single-Cell Platforms
- Functions with an approved “single point” STAINLESS STEEL C6 load cell according to OIML R60 standards with protection against dust and water splashes according to IP68 and IP69K standards.
- Structure with tubulars, mechanics, trinkets and loading surface in AISI304 satin finish stainless steel.
- Fitted with adjustable STAINLESS steel feet with plastic resting surface and level.
- Up to 15 Vdc power supply.
- Shielded 3m connection cable with connectors for connection to the indicator.
- Available in approved multi-range 3000+3000e or 6000+6000e, and multi-interval 2x3000e.
- Made in Italy.
AISI 304 Stainless Steel. Load cell in Stainless Steel. IP68 and IP69K protection rating.
Precision class C3, C3MR, C3MI, C6, C6MR.
TE 69K series platforms are known for their accuracy and robustness.
The AISI 304 stainless steel construction and IP68 and IP69K load cell protection make these platforms ideal for industrial and commercial applications in harsh environments with high humidity and water exposure.
The C6 accuracy class approved load cell provides accurate weighing to improve production quality and optimize raw material consumption.
Specifications
Multi Interval Version "-MI" Compared to the more common multi-range type approval, the multi-interval type approval offers ADAPTIVE measurement resolution, which automatically varies by adjusting to the weight being measured. NOTE: Multi-interval models are distinguished by the final "-MI" abbreviation and must be paired with a DFW or 3590 series Dini Argeo indicator, DiniCal calibration service and ECEM2MI approval service. |
Available upon price estimate
|
|
Available Versions
Code | l x w x h (mm) | Max (kg) | d (g) | M (g*) | d HR (g)* |
---|---|---|---|---|---|
TSE3-69K | 230x330x90 | 3 | 0,5 | See table below | 0,2 |
TSE3-69K-MI | 230x330x90 | 3 | -- | 0,5/1 (Multi interval) | -- |
TSE6-69K | 230x330x90 | 6 | 1 | See table below | 0,5 |
TSE6-69K-MI | 230x330x90 | 6 | -- | 1/2 (Multi interval) | -- |
TSE12-69K-MI | 230x330x90 | 12 | -- | 2/5 (Multi interval) | -- |
TSE15-69K | 230x330x90 | 15 | 2 | See table below | 1 |
TTE6-69K | 330x330x90 | 6 | 1 | See table below | 0,5 |
TTE6-69K-MI | 330x330x90 | 6 | -- | 1/2 (Multi interval) | -- |
TTE12-69K-MI | 330x330x90 | 12 | -- | 2/5 (Multi interval) | -- |
TTE15-69K | 330x330x90 | 15 | 2 | See table below | 1 |
TTE30-69K | 330x330x90 | 30 | 5 | See table below | 2 |
TTE30-69K-MI | 330x330x90 | 30 | -- | 5/10 (Multi interval) | -- |
TQE12-69K-MI | 400x400x115 | 12 | -- | 2/5 (Multi interval) | -- |
TQE15-69K | 400x400x115 | 15 | 2 | See table below | 1 |
TQE30-69K | 400x400x115 | 30 | 5 | See table below | 2 |
TQE30-69K-MI | 400x400x115 | 30 | -- | 5/10 (Multi interval) | -- |
TQE60-69K | 400x400x115 | 60 | 10 | See table below | 5 |
TQE60-69K-MI | 400x400x115 | 60 | -- | 10/20 (Multi interval) | -- |
TME30-69K | 400x500x115 | 30 | 5 | See table below | 2 |
TME30-69K-MI | 400x500x115 | 30 | -- | 5/10 (Multi interval) | -- |
TME60-69K | 400x500x115 | 60 | 10 | See table below | 5 |
TME60-69K-MI | 400x500x115 | 60 | -- | 10/20 (Multi interval) | -- |
Multi-interval Versions
C3 |
C6 |
|||||||||
ECEM 3000e |
ECEM2 3000+3000e |
ECEM2 MI 2x3000e |
ECEM-C6 6000e |
ECEM2-C6 6000+6000e |
||||||
Max (kg) | e (g) | Max (kg) | e (g) | Max (kg) | e (g) | Max (kg) | e (g) | Max (kg) | e (g) | |
TSE 230x330x90mm |
3 | 1 | 1,5/3 | 0,5/1 | 3 | 0,5/1 | 3 | 0,5 | -- | -- |
6 | 2 | 3/6 | 1/2 | |||||||
-- | -- | -- | -- | 12 | 2/5 | -- | -- | -- | -- | |
15 | 5 | 6/15 | 2/5 | -- | -- | 12 | 2 | 6/12 | 1/2 | |
TTE 330x330x90mm |
6 | 2 | 3/6 | 1/2 | 6 | 1/2 | 6 | 1 | 3/6 | 0,5/1 |
-- | -- | -- | -- | 12 | 2/5 | -- | -- | -- | -- | |
15 | 5 | 6/15 | 2/5 | -- | -- | 12 | 2 | 6/12 | 1/2 | |
30 | 10 | 15/30 | 5/10 | 30 | 5/10 | 30 | 5 | 12/30 | 2/5 | |
TQE 400x400x115mm |
-- | -- | -- | -- | 12 | 2/5 | -- | -- | -- | -- |
15 | 5 | 6/15 | 2/5 | -- | -- | 12 | 2 | 6/12 | 1/2 | |
30 | 10 | 15/30 | 5/10 | 30 | 5/10 | 30 | 5 | 12/30 | 2/5 | |
60 | 20 | 30/60 | 10/20 | 60 | 10/20 | 60 | 10 | 30/60 | 5/10 | |
TME 400x500x115mm |
30 | 10 | 15/30 | 5/10 | 30 | 5/10 | 30 | 5 | 12/30 | 2/5 |
60 | 20 | 30/60 | 10/20 | 60 | 10/20 | 60 | 10 | 30/60 | 5/10 |
Resources / Downloads
Articles
Title | View | Category | Type | |
---|---|---|---|---|
TE Platform Series: Ideal For Every Environment | Platform Scales | Articles | ||
How to Choose a Bench Scale | Bench Scales | Articles |
Parts
Available versions
Part # | Description | List Price | Cart / Quote | |
---|---|---|---|---|
TSE3-69K | Platform made of AISI304 stainless steel, IP68/IP69K, Max=3kg, e=0,5g, 230x330mm loading surface. 3m shielded cable. Stainless steel load cell in class C6. Optional calibration and approval services. |
Consult |
||
TSE3-69K-MI | Platform made of AISI304 stainless steel, IP68/IP69K, multi interval approved, Max=3kg, e=0,5/1g, 230x330mm loading surface. Stainless steel load cell in C6 class. 3m shielded cable. NOTE: Always to be combined with DINICAL or DINICAL-DRC and ECEM2MI service. |
Consult |
||
TSE6-69K | Platform made of AISI304 stainless steel, IP68/IP69K, Max=6kg, e=1g, 230x330mm loading surface. 3m shielded cable. Stainless steel load cell in class C6. Optional calibration and approval services. |
Consult |
||
TSE6-69K-MI | Platform made of AISI304 stainless steel, IP68/IP69K, multi interval approved, Max=6kg, e=1/2g, 230x330mm loading surface. Stainless steel load cell in class C6. 3m shielded cable. NOTE: Always to be combined with DINICAL or DINICAL-DRC and ECEM2MI service. |
Consult |
||
TSE12-69K-MI | Platform made of AISI304 stainless steel, IP68/IP69K, multi interval approved, Max=12kg, e=2/5g, 230x330mm loading surface. Stainless steel load cell in C6 class. 3m shielded cable. NOTE: Always to be combined with DINICAL or DINICAL-DRC and ECEM2MI service. |
Consult |
||
TSE15-69K | Platform made of AISI304 stainless steel, IP68/IP69K, Max=15kg, e=2g, 230x330mm loading surface. 3m shielded cable. Stainless steel load cell in class C6. Optional calibration and approval services. |
Consult |
||
TTE6-69K | Platform made of AISI304 stainless steel, IP68/IP69K, Max=6kg, e=1g, 330x330mm loading surface. 3m shielded cable. Stainless steel load cell in class C6. Optional calibration and approval services. |
Consult |
||
TTE6-69K-MI | Platform made of AISI304 stainless steel, IP68/IP69K, multi interval approved, Max=6kg, e=1/2g, 330x330mm loading surface. Stainless steel load cell in C6 class. 3m shielded cable. NOTE: Always to be combined with DINICAL or DINICAL-DRC and ECEM2MI service. |
Consult |
||
TTE12-69K-MI | Platform made of AISI304 stainless steel, IP68/IP69K, multi interval approved, Max=12kg, e=2/5g, 330x330mm loading surface. Stainless steel load cell in C6 class. 3m shielded cable. NOTE: Always to be combined with DINICAL or DINICAL-DRC and ECEM2MI service. |
Consult |
||
TTE15-69K | Platform made of AISI304 stainless steel, IP68/IP69K, Max=15kg, e=2g, 330x330mm loading surface. 3m shielded cable. Stainless steel load cell in class C6. Optional calibration and approval services. |
Consult |
||
TTE30-69K | Platform made of AISI304 stainless steel, IP68/IP69K, Max=30kg, e=5g, 330x330mm loading surface. 3m shielded cable. Stainless steel load cell in class C6. Optional calibration and approval services. |
Consult |
||
TTE30-69K-MI | Platform made of AISI304 stainless steel, IP68/IP69K, multi interval approved, Max=30kg, e=5/10g, 330x330mm loading surface. Stainless steel load cell in C6 class. 3m shielded cable. NOTE: Always to be combined with DINICAL or DINICAL-DRC and ECEM2MI service. |
Consult |
||
TQE12-69K-MI | Platform made of AISI304 stainless steel, IP68/IP69K, multi interval approved, Max=12kg, e=2/5g, 400x400mm loading surface. Stainless steel load cell in C6 class. 3m shielded cable. NOTE: Always to be combined with DINICAL or DINICAL-DRC and ECEM2MI service. |
Consult |
||
TQE15-69K | Platform made of AISI304 stainless steel, IP68/IP69K, Max=15kg, e=2g, 400x400mm loading surface. 3m shielded cable. Stainless steel load cell in class C6. Optional calibration and approval services. |
Consult |
||
TQE30-69K | Platform made of AISI304 stainless steel, IP68/IP69K, Max=30kg, e=5g, 400x400mm loading surface. 3m shielded cable. Stainless steel load cell in class C6. Optional calibration and approval services. |
Consult |
||
TQE30-69K-MI | Platform made of AISI304 stainless steel, IP68/IP69K, multi interval approved, Max=30kg, e=5/10g, 400x400mm loading surface. Stainless steel load cell in C6 class. 3m shielded cable. NOTE: Always to be combined with DINICAL or DINICAL-DRC and ECEM2MI service. |
Consult |
||
TQE60-69K | Platform made of AISI304 stainless steel, IP68/IP69K, Max=60kg, e=10g, 400x400mm loading surface. 3m shielded cable. Stainless steel load cell in class C6. Optional calibration and approval services. |
Consult |
||
TQE60-69K-MI | Platform made of AISI304 stainless steel, IP68/IP69K, multi interval approved, Max=60kg, e=10/20g, 400x400mm loading surface. Stainless steel load cell in C6 class. 3m shielded cable. NOTE: Always to be combined with DINICAL or DINICAL-DRC and ECEM2MI service. |
Consult |
||
TME30-69K | Platform made of AISI304 stainless steel, IP68/IP69K, Max=30kg, e=5g, 400x500mm loading surface. 3m shielded cable. Stainless steel load cell in class C6. Optional calibration and approval services. |
Consult |
||
TME30-69K-MI | Platform made of AISI304 stainless steel, IP68/IP69K, multi interval approved, Max=30kg, e=5/10g, 400x500mm loading surface. Stainless steel load cell in C6 class. 3m shielded cable. NOTE: Always to be combined with DINICAL or DINICAL-DRC and ECEM2MI service. |
Consult |
||
TME60-69K | Platform made of AISI304 stainless steel, IP68/IP69K, Max=60kg, e=10g, 400x500mm loading surface. 3m shielded cable. Stainless steel load cell in class C6. Optional calibration and approval services. |
Consult |
||
TME60-69K-MI | Platform made of AISI304 stainless steel, IP68/IP69K, multi interval approved, Max=60kg, e=10/20g, 400x500mm loading surface. Stainless steel load cell in C6 class. 3m shielded cable. NOTE: Always to be combined with DINICAL or DINICAL-DRC and ECEM2MI service. |
Consult |
Options
Calibration service with weight indicator
Part # | Description | List Price | Cart / Quote | |
---|---|---|---|---|
DINICAL | Connection to a Dini Argeo indicator and calibration. NET PRICE (*). |
Consult |
||
DINICAL-DRC | Connection to a Dini Argeo indicator and calibration. NET PRICE. |
Consult |
Legal for trade approval , class III or IIII, with Dini Argeo indicator (only at time of order)
HR calibration (high resolution) with Dini Argeo indicator (only at time of order)
Connection cables
Columns, supports brackets, visors
Charts for mobile weighing applications
Raising Frame
Calibration service with Dini Argeo indicator (only at time of order)
Related Products
New TE HYGIENX® Series Single Cell Platforms
Made entirely of AISI 316 stainless steel in Italy, the platform is entirely washable to prevent the build-up of bacteria in the most critical spots.
TE C6 Series Single-Cell Platforms
Small and medium capacity electronic platforms, having a precise and sturdy structure, are particularly suitable for all types of industrial and commercial applications in which it's necessary to work in environments with strict hygiene requirements. 6000e legal for trade version.
TE Series Single-Cell Platforms
Small and medium capacity electronic platforms, having a precise and sturdy structure, are particularly suitable for all types of industrial and commercial applications in which it's necessary to work in environments with strict hygiene requirements.
PBI Series Single-Cell Platforms
Small and medium capacity electronic platforms with a stainless steel surface having a precise and sturdy structure. Suitable for creating scales and automatic weight checking systems for all industrial and commercial applications. The standard version is provided with approved load cell.