ATEX/IECEX Triple Zener Barrier for Load Cells ZBA1S

  • Three channels passive zener barrier for power supply, reference and signal. Ex marking: ATEX II (1)G, II (1)D, I (M1)IECEx [circuit(s) in zone 0/1/2]

  • Protection: [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I (-20 °C ≤ Tamb ≤ +60 °C)

  • Equipped with 3 channels for the protection of the Signal line (CN1/CN4), the Excitation line (CN3/CN6) and the Sense line, for improved signal stability.
  • “SLIM” type case, iper-compact, for DIN rail installation.
  • Temperature of usage: -20°C ÷ +60°C.
  • Storage temperature: -25°C ÷ +70°C
  • Rating: 14Vrms differential and 8Vrms through earth for CN3 connector, 20Vrms for the CN1 & CN2
  • Maximum Security Voltage(Um): 250Vrms
  • Maximum Security Current (current interruption capability): 1500A
  • Degree of protection: IP20
  • Excitation, Signal and Sense Marking: ATEX II (1)G, II(1)D, I(M1)
  • Protection: [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I (-20°C ≤ Tamb ≤ +60°C)

  • NOTE:
  • Can connect up to 4 Load Cell of 350 Ohm.
  • Combined use of one or more Zener Barriers (1) GD [Ex ia], implies that the Atex marking of the set of barriers must be upgraded (2) GD [Ex ib], as written in the EN 60079-14 normative.

KZBA Case Features:

  • Material: ABS
  • Glands: n.4, ATEX certified.
  • Protection for Case + Barrier:
    for gas:
    - ATEX II 3(1) Ex nAa [ia Ga] IIC T4 Gc (-20°C ≤ Ta ≤ +50°C)
    for dust:
    - ATEX II 3(1)D Ex tb [ia Da] IIIC T130°C Dc IP65 (-20°C ≤ Ta ≤ +50°C)

The Zener Barrier ZBA1S is the perfect solution for the connection between a weighing terminal and a weight receiver system in the ATEX ZONE. ZBA1S integrates three barriers in one, protecting the excitation line, signal and sense. This feature makes the installation easier, especially in small spaces. This saves time and money.

Resources / Downloads

Title View Email Category Type
All Around Dini Argeo Weighing Solutions for Logistics and Warehouses Email Pallet Truck Scales|Pallet Scales|Pallet Weighers|Electric Pallet Truck Scales|Ex Pallet Truck Scales|Hygienic Pallet Truck Scales|Pallet Weighing|Weighing Forks|Hydraulic Weighing|Counting Scales|Bench Scales|Axle Weighing Scales|In-Motion Axle Scales|Dynamic Axle Weighing|Weighing Axle Platforms and Indicators|High Resolution Load Cells|Off Center Load Cells|Bending Beam Load Cells|Shear Beam Load Cells|Double Shear Beam Load Cells|Compression Load Cells|Tension Load Cells|Column Load Cells|Assembly Kit Load Cells|Ex Load Cells|Hygienic Load Cells Articles