SPO Series Single Point Load Cells

  • C3 precision class
  • Off center load compensated
  • Aluminium alloy construction
  • IP67 protection
  • Max. capacities from 3 to 40 kg
  • For platforms with dimensions up to 300 x 300 mm
  • Shielded connection cable
  • OIML and test certificates available upon request
OIML Atex

CAPACITIES (kg): 3, 5, 10, 15, 20, 30, 40.


OIML R60. C3 precision class.


Aluminium alloy. IP67 protection.

Load cells for off center loads, suitable for example to build CE-M approved scales with a single load cell with maximum dimensions of 300x300 mm.

Minimum load cell verification interval:
Vmin = EMax/8.000-15.000

Maximum number of verification intervals:
nLC = 3000

Full Scale Output:
2mV/V +/- 10%

Temperature effect on zero:
from ±0,0093% F.S./10K to ±0,0175% F.S/10K

Temperature effect on full scale output:
0,0117% F.S./10K (-10°C/+20°C) 0,0175% F.S./10K (+20°C/+40°C)

Compensated Temperature Range:
-10°C/+40°C

Operating Temperature Range:
-10°C/+50°C

Maximum tolerated excitation voltage:
15 VDC

Input Resistance:
300..500 Ohm

Output Resistance:
300..500 Ohm

Insulation Resistance:
>2000 MOhm

Safe Overload:
150% F.S.

Ultimate Overload:
300% F.S.

Shielded cable:
4-wire shielded cable, 40cm long, 3,2mm diameter

 

Wiring Code
Color
Function
YELLOW
SHIELD
WHITE
OUTPUT +
BLUE
INPUT +
RED
OUTPUT -
BLACK
INPUT -

 

The CCATEX certificate makes the load cell suitable for use in hazardous areas with protection methods according to:

ATEX II 1G Ex ia IIC T6 (Ta -20÷+40°C) TX (Ta -20÷+65°C) Ga
ATEX II 1D Ex ta IIIC TX°C (Ta -20÷+40°C) TX°C (Ta -20÷+65°C) Da IP65

The certificate includes the manual and the ATEX CE conformity declaration (available in EN, DE, FR, and IT).

IMPORTANT: the certificate refers to the single load cell. For systems with more load cells, it is necessary to order one certificate for each load cell.

Code Max
(kg)
Plate Max
(mm)
l
(mm)
w
(mm)
h
(mm)
a
(mm)
b
(mm)
c Ø
(mm)
d
(mm)
e
(mm)
f
(mm)
SPO3-1 3 150 x 150 130 25,4 22 106 15 N°4 x M6 25 12 5
SPO5-1 5 300 x 300 130 25,4 22 106 15 N°4 x M6 25 12 5
SPO10-1  10 300 x 300 130 25,4 22 106 15 N°4 x M6 25 12 5
SPO15-1  15 300 x 300 130 25,4 22 106 15 N°4 x M6 25 12 5
SPO20-1 20 300 x 300 130 25,4 22 106 15 N°4 x M6 25 12 5
SPO30-1  30 300 x 300 130 25,4 22 106 15 N°4 x M6 25 12 5
SPO40-1

40

300 x 300 130 30 22 106 15 N°4 x M6 25 12 5

Resources / Downloads

Title View Email Category Type
All Around Dini Argeo Weighing Solutions for Logistics and Warehouses Email Pallet Truck Scales|Pallet Scales|Pallet Weighers|Electric Pallet Truck Scales|Ex Pallet Truck Scales|Hygienic Pallet Truck Scales|Pallet Weighing|Weighing Forks|Hydraulic Weighing|Counting Scales|Bench Scales|Axle Weighing Scales|In-Motion Axle Scales|Dynamic Axle Weighing|Weighing Axle Platforms and Indicators|High Resolution Load Cells|Off Center Load Cells|Bending Beam Load Cells|Shear Beam Load Cells|Double Shear Beam Load Cells|Compression Load Cells|Tension Load Cells|Column Load Cells|Assembly Kit Load Cells|Ex Load Cells|Hygienic Load Cells Articles
How to Choose the Best Load Cell for Your Needs Email Load Cell Articles

Parts

Available Versions

Part # Description List Price Cart
SPO3-1 Single point approved load cell, C3, Max=3kg in aluminium alloy, IP67 protection degree, 350 Ohm output resistance.

Call for price

SPO5-1 Single point approved load cell, C3, Max=5kg in aluminium alloy, IP67 protection degree, 350 Ohm output resistance.

Call for price

SPO10-1 Single point approved load cell, C3, Max=10kg in aluminium alloy, IP67 protection rating, 350 Ohm output resistance.

Call for price

SPO15-1 Single point approved load cell, C3, Max=15kg in aluminium alloy, IP67 protection degree, 350 Ohm output resistance.

Call for price

SPO20-1 Single point approved load cell, C3, Max=20kg in aluminium alloy, IP67 protection degree, 350 Ohm output resistance.

Call for price

SPO30-1 Single point approved load cell, C3, Max=30kg in aluminium alloy, IP67 protection degree, 350 Ohm output resistance.

Call for price

SPO40-1 Single point approved load cell, C3, Max=40kg. Aluminium alloy, IP67 protection degree, 350 Ohm output resistance.

Call for price

Options

Options for ATEX version

Part # Description List Price Cart
LCCB Shielded cable 6x0.25 mmý (suitable for Ex zones). PVC inner sheath. Tinned copper braid shielding. PVC outer sheath, diameter 5.8 mm. Temperature range: -40 / +80 øC. Minimum bending radius >/= 6 x O.D. _/m

Call for price

LCCBA Armoured cable 6x0.25 mmý (suitable for Ex zones). PVC inner sheath, diameter 5mm. Iron-zinc alloy armour. Transparent PVC outer sheath, 8 mm diameter. Temperature range: -15 / +70 øC. Minimum bending radius >/= 5 x O.D. _/m

Call for price

EXCB6 Blue shielded cable 6x0.22 mmý, only for EX i (2GD) assemblies. PVC inner sheath. Tinned copper braid shielding. Polyurethane outer sheath, diameter 5.8 mm. Temperature range: -40 / +80 øC. Minimum bending radius >/= 7 x O.D. _/m

Call for price

CCATEX-1 Optional ATEX version for single load cell. Marking: ATEX II 1G Ex ia IIC T6 (Ta -20ö+40øC) TX (Ta -20ö+65øC) Ga and ATEX II 1D Ex ta IIIC TXøC (Ta -20ö+40øC) TXøC (Ta -20ö+65øC) Da IP65. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT).

Call for price

CCATEX3GD ATEX certificate for each load cell. Marking: ATEX II 3G Ex nA IIC T6 Gc for gas and ATEX II 3D Ex tc IIIC T115øC Dc IP65 for dusts. Complete with manual and ATEX CE conformity declaration (available in EN, DE, FR and IT).

Call for price