MSI-9000 CellScale™ Wireless Weighing Solution

(Contact MSI for application consultation)

  • 2.4 GHz frequency hopping spread spectrum
  • Two scale inputs and excitation with remote sensing (see formatting connector accessory)
  • Power/switch cable, 13 ft (4 m) for 9 to 30 VDC input with two programmable switch inputs
  • RS-232, RS-422 and RS-485 I/O with 13 ft (4 m) interface cable
  • Three internal solid state relays for setpoint control
  • Real-time clock
  • NEMA Type 4, IP65 enclosure (NEMA Type 6, IP67 with long-range antenna)

Approvals

Some approval documents are available to view by clicking the icons below.

NTEP Logo

WARNING: Cancer and Reproductive Harm California Proposition 65

A Versatile, Wireless Weighing Solution

The MSI-9000 CellScale™ is MSI’s most innovative and technologically advanced product for wireless weighing and networked system solutions for industrial plant applications.

The MSI-9000 CellScale simultaneously processes, monitors and controls single or multiple load sensor inputs and outputs along with real-time communications over a secure FHSS 2.4GHz RF network. Up to 64 selectable license-free RF networks are available ensuring reliable non-interfering transmissions across nearly all industrial environments.

The MSI-9000 functions as the central controller in a CellScale networked weighing system combining advanced analog-to-digital (A/D) processing with superior RF communications packaged in a NEMA 4 /IP65 industrial grade enclosure. A standard CellScale can process two load sensor inputs or with an optional second A/D module, up to four inputs simultaneously with real-time data collection and communication throughout a network of peripheral CellScale weighing components.

Other CellScale weighing components providing versatile wireless weighing system solutions include: MSI-9750A & MSI-9850 RF remote indicators, MSI-6260CS, MSI- 9300 & MSI-9300HT RF industrial crane scales, and MSI RF remote scoreboards. The MSI-9020 cell modem also provides simple network connectivity with existing plant information systems and equipment, including: printers, computers and PLCs.

Enclosure:
NEMA Type 4, IP65 milled anodized aluminum with O-ring gaskets
NEMA Type 6, IP67 with optional long range antenna

Weight:
3.5 lb (1.6 kg)

Annunciators:
8 LED status lamps for Power, Setpoints, Comm Port, Excitation & RF Modem

Real-Time Clock:
USA or European format programmable

Power Input:
9 to 30 VDC (Internal 85 to 265 VAC power supply optional)

Operating Temperature:
-4 °F to 158 °F (-20 °C to 70 °C)
Legal for Trade: 14 °F to 104 °F (-10 °C to 40 °C)

Scale Inputs:
2 sensor inputs and 6 terminal connections

Excitation:
5 V (+5 V relative to ground)

Calibration:
Digital via input comport or RF with other CellScale weighing components
Programmable calibration settings include: AZM, Motion, Filter, Zero, Units, Capacity and Divisions

Digital Filtering:
Two-stage programmable digital filtering

Totalization, Statistics and Product IDs:
Push-button or automatic with each ID register. Up to 32 alphanumeric ID registers.

Radio Link:
FHSS at 2.4 GHz (up to 64 network selections)

Radio Link Effective Range:
Typically 500 ft (150 m) indoor, 1,000 ft (300 m) outdoor with standard antennas (See
optional antennas for longer range)

Standard Antenna:
1/2 wave 2dBi, articulated

RFI/EMI Shielding:
Exceeds NIST HB44 and CE Standards

Data I/O:
2 programmable comports supporting RS-232 or RS-422

Push Button Inputs:
2 inputs on power connector and 1 isolated input on setpoints connector

Connectors:
12-pin MIL-C-26482 for load sensor input Turck compatible Pico for RS-232 output

Math Channels:
8 math channels programmable for arithmetic formula processing

Internal Setpoints:
3 60 V at 350 mA internal programmable solid state relay contacts

Warranty:
One-year limited

Approvals:
NTEP CC 05-077
Measurement Canada AM-5781

Resources / Downloads

Title Download Email
MSI-9000 CellScale Catalog Page Download Email

Title Version Revision Download Email Category Archived
MSI-9000 Calibration Guide Download Email MSI Crane Scales No
MSI-9000 Operator's Manual Download Email MSI Crane Scales No
MSI-9000 Setup Exit Guide Download Email MSI Crane Scales No
MSI-9000 Software Upgrade Guide Download Email MSI Crane Scales No

Title Download Email
MSI-9000 Replacement Parts Page Download Email
MSI-9002 Replacement Parts Page Download Email

Title Collateral Wizard Request Download Email Category
Crane Scale Selection Guide Request Download Email MSI Crane Scales|Overhead Weighing Systems
MSI Overhead Weighing Product Guide Request Download Email MSI Crane Scales
MSI-9000 CellScale RF Wireless Weighing Solutions Request Download Email MSI Crane Scales
Sea Port Monitoring Solutions Request Download Email MSI Crane Scales
The Overhead Weighing Solutions Buyer's Guide Request Download Email Systems Integration/Load Cells|Tension Dynamometers|MSI Software|MSI Aircraft Load Monitoring|MSI Crane Scales|Overhead Weighing Systems
Why Buy MSI? Download Email MSI Crane Scales|Overhead Weighing Systems
6 Step Integrated Crane Weighing Component Selector Guide Request Download Email MSI Crane Scales|Overhead Weighing Systems

Title View Download Email Category
Ensure Safety with MSI View Download Email Overhead Weighing Systems|MSI Crane Scales|Systems Integration/Load Cells|Hanging Scales|MSI Software|MSI Aircraft Load Monitoring
Types of Crane Scales View Download Email Overhead Weighing Systems

Options

Options

Part # Description List Price Cart / Quote
144331 ANTENNA 2.4GHz 5dBi VEHICLE MOUNT TNC

Consult

144091 CORDSET IP68 4 PIN MALE 4 COND PUR 4M

Consult

143343 CORDSET IP68 5 PIN FEMALE SHIELDED 4M

Consult

143297 CONN CYL STRAIGHT PLUG #14 SHL MS3116F-14-12P

Consult

143466 ANTENNA 2.4 GHz MAST MOUNT 9dBi TNC

Consult

144330 ANTENNA CORNER 2.4GHz 9dBi MAST MOUNT N

Consult

144334 CABLE ASSY,RF-195 COAX N TO TNC 10 FEET

Consult

143977 ANTENNA YAGI 15dbi GAIN CS

Consult

144332 ANTENNA CABLE 2.4GHz VEHICLE MOUNT

Consult

148624 Cable Assembly RS232/485 To DB-9, For Scale Calibration And Configuration.

List Price: $140.00

Consult NTEP Certified (contact factory for specifications)

Consult

Consult Internal AC/DC power supply (85-265 VAC, 47-440 Hz/130-300 VDC) includes a separate, independent 9-30 VDC power input

Consult

Consult Single or dual 4-20 mA output. Provides programmable current output for direct connection to PLC’s and other data acquisition equipment. Note: See 4-20 mA option specification sheet for available product configurations

Consult

Consult Nonterminated serial cable for communication port connection, 13 ft/4 m (longer lengths available by special order)

Consult

Consult Prewired load cell cable (various lengths for single and dual channel available)

Consult

Consult Second A/D module (4 scale inputs - adds second 12-Pin connector)

Consult

Consult CellScale Virtual Monitor (CVM) application software (enables PC to emulate scale indicator., contact factory for assistance)

Consult

Consult Modem only equipped version (CellScale A/D removed)

Consult

Consult Non-RF equipped version (CellScale RF modem removed)

Consult

Consult Wi-Fi Ethernet Connectivity (802.11b - contact factory for assistance)

Consult

Consult Long range antenna, 300-500 m omni-directional with 9 dBi gain, includes 10 ft/3 m coaxial cable

Consult

Replacement Parts

Replacement parts can only be purchased through trained and authorized dealers. You must be logged in as a dealer to view any available replacement parts.

To locate a dealer in your area, please call us at 1-800-472-6703 or fill out a request online.