Flintec® PCB Stainless Steel, Single Point Load Cell
Standard Features
A unique "brick" style of load cell. Constructed of stainless steel and hermetically sealed, this unique design provides superior protection in applications where moisture and high humidity are problems. This model features both a welded gauge cavity area, and waterproof cable entry for long-lasting performance. Provides an upgrade from aluminum to stainless steel. Available in capacities from 50 kg to 1,000 kg. Each unit includes 10 ft of load cell cable.
PCB Load Cell Specifications
Full Scale Output: Output Resistance: Input Resistance: Material/Finish: Temperature: Seal Type: |
Safe Overload: Safe Sideload: Rated Excitation: Combined Error: Insulation Resistance: Deflection at Capacity: Cable Length: |
Cable Diameter: Cable Color Code: Max Platform Size: Warranty: Approvals: |
PCB Load Cell Dimensions
Rated Capacity | L | L1 | L2 | W | W1 | H |
---|---|---|---|---|---|---|
kg/mm | ||||||
50 to 1,000 | 190.5 | 124.8 | 24.9 | 74.9 | 59.9 | 74.9 |
Parts
Part # | Description |
---|---|
45274 | Load Cell,SPT PCB-50kg C3 10ft Flintec 2mV/V 1000 OHM NTEP III 5 S FM SST HS IP69K OIML C3 |
45275 | Load Cell,SPT PCB-100kg C3 10ft Flintec 2mV/V 1000 OHM FM SST HS IP69K NTEP III 5 S OIML C3 |
45276 | Load Cell,SPT PCB-250kg C3 10ft Flintec 2mV/V 1000 OHM FM SST HS IP69K NTEP III 5 S OIML C3 |
45277 | Load Cell,SPT PCB-500kg C3 10ft Flintec 2mV/V 1000 OHM FM SST HS IP69K NTEP III 5 S OIML C3 |
45278 | Load Cell,SPT PCB-1000kg C3 10ft Flintec 2mV/V 1000 OHM FM SST HS IP69K NTEP III 5 S OIML C3 |
Options
Part # | Description |
---|---|
17703 | Adapter,Conduit 1/2-14NPT Male For SB4/UB1 SST |
An ISO 9001 Registered Company ©2024 Rice Lake Weighing Systems