UJB3T6 DC Transient Protector
Standard Features
- Protects load cells from voltage transients
- Compatible with signals down to 1 μV per grad
- Factory serviceable
- Full six-wire with shield protection
- #6 SEMS screw type; accepts spade lugs, tinned leads or bare wires up to #12 AWG
- Up to eight parallel or summed load cells
- Installations exposed to significant transients
- Protects serial communication lines
- Protects load cells
The factory-serviceable UJB3T6 DC Transient Protector can protect up to six data lines or eight load cells. The fiberglass reinforced polyester enclosure can withstand up to 40 psi in washdown applications.
UJB3T6 DC Transient Protector Specifications
Protection Type: Maximum Excitation Voltage: Clamping Voltage: Clamping Time: Peak Surge Currents: Maximum Serial Transmission Rate: |
Series Resistance: Series Inductance: Grounding: Cable Fitting: Enclosure: |
Temperature: Circuit Board: Dimensions: Warranty: |
UJB3T6 DC Transient Protector Dimensions
Parts
Part # | Description |
---|---|
21134 | Transient Protection, UJB-3T6 Load Cell Protection |
Options
Part # | Description |
---|---|
21135 | Board,UJB-3T6 Board Only |
An ISO 9001 Registered Company ©2024 Rice Lake Weighing Systems