DGT60: Maxi GOLIAH Weight Indicator/Universal Repeater
Standard Features
- Functional 5-key waterproof keypad.
- Large 6-digit display, 60 mm high, with very efficient SMD LEDs (software adjustment of the brightness intensity), complete of 6 Leds for indication of active functions, visible from over 25 m, with viewing angle up to 120° and with power up to 750 mcd.
- IP68 stainless steel case complete of wall fixing bracket.
- Dimensions: 410 x 67 x 165 mm.
- Calibration, Set-Up parameters, configurable from keyboard or from PC with DINI TOOLS.
- Max. 10.000e or multirange 2 x 3000e @ 0,3 µV/e in CE-M approved version for legal for trade use.
- Max. 800.000 displayable divisions viewable with internal resolution up to 3.000.000 points.
- Up to 8 signal linearisation points with DINITOOLS.
- A/D 24 bit sigma-delta 4-channel conversion, max.400 conv./sec. with automatic selection.
- Connectable with up to 8 analogue load cells with 350 Ohm input resistance.
- Management of a weighing system with up to 4 cells with digital equalisation or management of up to 4 independent weighing systems.
- Power supply from 12 to 24 Vdc with 110-240 Vac internal power supplier.
- Available as Scale or as Repeater version.
- Fitted with an air valve for regulating the humidity and the pressure inside the indicator.
Weight indicator/ repeater with large matrix display composed of very intense bright LEDs. Particularly suitable for use outdoors, also in full sunlight, and where it's necessary to view from a distance at any angle. Case completely in IP68 stainless steel.
Specifications
FUNCTIONS:
|
I/O SECTION: MASTER/REPEATER OPTIONS: Functioning Modes: |
CERTIFICATIONS: |
Parts
Part # | Description |
---|---|
Available Versions | |
DGT60BC-1 | Weight indicator with 60mm LED display. IP68 stainless steel case, 5-key keypad, and air valve for regulating the humidity and the pressure. |
DGT60R-1 | Weight repeater with 60 mm LED display. IP68 stainless steel case, 5-key keypad, air valve for regulating the humidity and the pressure, and configurable protocol. |
DGT60AN-1 | Weight indicator with 60mm LED display and analogue output. IP68 stainless steel case, 5-key keypad, and air valve for regulating the humidity and the pressure. |
DGT60PB-2 | Weight indicator with 60mm LED display and Profibus. IP68 stainless steel case, 5-key keypad, and air valve for regulating the humidity and the pressure. |
Options
Part # | Description |
---|---|
RS485 lightning and surge protection | |
RS485PDIN | Protection circuit for port 485, with enclosure for DIN rail installation. Protection according to IEC 1000-4-5/D (IEC 801-5/D). |
Optional power supply cords | |
PWCORDUK | Power supply cord with BS1363 plug (UK plug). |
PWCORDCH | Power supply cord with SEV1011 plug (CH plug). |
PWCORDUS | Version with US type B power cord (Japan, North and Central America). |
PWCORDAUS | Version with AU power cord. |
Visor and brackets | |
STFR-1 | AISI 304 stainless steel fixing bracket with adjustable inclination. For weight indicator wall mounting. |
Approval for sale to third parties | |
KCEM | Plates and Welmec form for legal trade use of a scale. NET PRICE. Service available in combination with a Dini Argeo indicator. |
ECEM-AU | Single platform/scale legal-for-trade approval for Australia. |
Junction Box / Boards - Load Cell cables | |
LCCBC | Cable for connection between platform and indicator, l=50cm. Female connector to be soldered. |
LCCB5C | LCCBC cable + 5m extension cable. |
LCCB10C | LCCBC cable + 10m extension cable. |
Communication Interfaces | |
SETHDIN-1 | RS232 / RS485 / Ethernet converter. Modbus RTU / Modbus TCP/IP (if applicable). Connectable to all Dini Argeo weight indicators via the serial port. ABS housing for DIN rail. With PCB, screw terminals, plastic box and UL marked labels (if applicable). |
RSCBUSBPG | USB PC/RS232 converter cable, l=1,5m, with PG9. USB/RJ11 connector. For the connection to weight indicators with IP65 and IP68 protection system. |
OBRF2G4 | External 2.4 GHz radio module, cable l=3m. ABS IP65 protecting box, 3 m cable, power supply from weight indicator. Max. distance, in appropriate environmental and installation conditions: 45 m indoors, 140m outdoors. 39 configurable channels. |
OBRF2G4-USB | External 2.4 GHz radio frequency module, USB cable l=1m. Power supply directly from the USB port. Max. functioning distance, in appropriate environmental and installation conditions: 45 m indoors, 140 outdoors. 39 configurable channels. |
ALMEM-1 | Alibi memory (fiscal memory, max 120.000 weighs) for approved weight transmission to PC/PLC or data recording on MMC/USB. Built-in real time clock to print the date/time with PCB, screw terminal, plastic box and UL-marked labels (if applicable). |
ETHD | Built-in Ethernet interface. Speed from 10 to 100 Mbps, TCP, UDP, IP, ARP, ICMP, Ethernet Mac protocols. |
WIFITPWLK-2 | (S1) Built-in WI-FI interface. For wireless connection (through access point) to the company computer system. |
Date&Time option | |
DFCLK | Real time clock for printing/displaying of date and time. With UL marked PCB, screw terminal, plastic box and labels (if applicable). |
Connection cables | |
RSCBPC | RS232 cable l=1,5m with PG9 and wires for terminal board. |
RSCB5 | RS232 cable l=5m. For the connection of the weight indicator to a weight repeater, without connectors. |
RSCB10 | RS232/C cable l=10m. For the connection of the weight indicator to a weight repeater, without connectors. |
ETHCBRJ | Ethernet cable, l=1,5m. Fitted with fairlead, for connection between indicator and PC network. |
Options for ATEX version | |
ZBA1S | Intrinsic protection three channel Zener barrier. Specific for connection to load cells, for mounting on DIN rail in a safe area, or in a flame-proof case. Marking: ATEX/IECEx II (1) GD [Ex ia Ga] IIC [Ex ia Da] IIIC. Manual and ATEX UE CONFORMITY DECLARATIONS (available in EN, DE, FR, ES and IT). |
ZBINST | Installation of the ZBA1S / PFB485EX zener barrier inside the indicator case. Note: The cable (LCCB for barrier ZBA1S, RSCBTW for barrier PFB485EX) of the desired length must also be purchased. NET PRICE. |
LCCB | Shielded cable 6x0.25 mmý (suitable for Ex zones). PVC inner sheath. Tinned copper braid shielding. PVC outer sheath, diameter 5.8 mm. Temperature range: -40 / +80 øC. Minimum bending radius >/= 6 x O.D. _/m |
PFB485EX | Protection barrier for RS485, for direct connection in safe area. Max cable length: 200m. |
RSCBTW | 4-core twisted shielded cable (2x2x0.34 mmý), for RS485 communication or analogue output. Polyolefin inner sheath. Tinned copper braid shielding. Outer sheath PVC, diameter 7mm. Temperature range: -30 / +80 øC. Minimum bending radius >/= 6 x O.D. _/m |
KZBA-1 | ATEX ABS housing kit with Zener Barrier ZBA1S for load cells. For intrinsically safe weighing systems in a dangerous zone. Dimensions 179x359x166,5mm. It can connect up to 8 350 Ohm load cells. Marking of housing + Zener Barrier ZBA1S: ATEX II 3(1)G Ex nA [ia Ga] IIC T4 Gc X for gas, ATEX II 3(1)D Ex tc [ia Da] IIIC T135øC Dc IP66 X for dust. Provided with safety instructions and the ATEX EU declaration of conformity (EN and IT). |
DCATEXMB4 | ATEX declaration for the whole system with Dini Argeo Zener barriers. Ex II 2G IIC T6 Gb X e Ex II 2D IIIC T125øC Db X system, with label of the whole system, for weight indicator connected to Dini Argeo zener barriers, connected to a mechanical structure with ATEX load cells (each cell must be certified with CCATEX option). Provided with descriptive document of the assembly and ATEX EU declaration of conformity of the assembly (EN and IT). |
KMB4-1 | Kit of 3 ATEX Zener barriers for load cells, in an ABS box. For up to 4 load cells of 350 ohm, for intrinsic protection weighing systems in a dangerous area. Marking of the whole box with three Zener barriers: ATEX II 3(1)G Ex nA [ia Ga] IIC T4 Gc (-20øC = Ta = +40øC) for gas, ATEX II 3(1)D Ex tb [ia Da] IIIC T130øC Dc IP65 (-20øC = Ta = +40øC) for dusts. Provided with safety instructions and the ATEX EU declaration of conformity (EN and IT). |
Remote control | |
TLRD | Radio frequency remote control and receiver. Specific for DGT60/DGT100. |
PG cable glands | |
PG9M | 10 PG9 metallic cable gland set for weight indicators. |
PG9PG11C | Kit of 10 metalic IP68 from PG9 to PG11 adapters (o max cable 12mm) |
PG9PG13C | Kit of 10 metalic IP68 from PG9 to PG13 adapters (o max cable 12mm) |
Other accessories / options | |
TECMAN | Printed technical manual (Free download from the website). |
TECSUP | Technical assistance by telephone upon request. |
UMAN | Printed user manual (Free download from the website). |
ECEMDOC | Printed EU declaration of conformity, EU certificate of verification, test certificate and metrological book (free download from our website, only for approved CE-M products). NET _. |