DGT603GD Maxi GOLIAH Weight Indicator-Repeater for Hazardous Areas
Standard Features
- Functional 5-key waterproof keypad.
- Large 6-digit display, 60 mm high, with very efficient SMD LEDs (software adjustment of the brightness intensity), complete of 6 Leds for indication of active functions, visible from over 25 m, with viewing angle up to 120° and with power up to 750 mcd.
- IP68 stainless steel case complete of wall fixing bracket.
- Calibration, Set-Up parameters, configurable from keyboard or from PC with DINI TOOLS.
- Max. 10.000e or multirange 2 x 3000e @ 0,3 µV/e in CE-M approved version for legal for trade use.
- Max. 800.000 displayable divisions viewable with internal resolution up to 3.000.000 points.
- Up to 8 signal linearisation points with DINITOOLS.
- A/D 24 bit sigma-delta 4-channel conversion, max.400 conv./sec. with automatic selection.
- Connectable with up to 8 analogue load cells with 350 Ohm input resistance.
- Management of a weighing system with up to 4 cells with digital equalisation or management of up to 4 independent weighing systems.
- Power supply from 110-240 Vac.
- Available as Scale or as Repeater version.
Weight indicator/ repeater particularly suitable for use in hazardous environments, where it's necessary to view the weight from a distance at any angle. Usable in areas:
- ATEX II 3G Ex nR IIC T6 Gc X for gases
- ATEX II 3D Ex tc IIIC T85°C Dc IP68 X for dust.
Fitted with a very bright 60mm LED matrix display and IP68 stainless steel case. CE-M approvable (OIML R-76 / EN 45501).
DGT603GD Maxi GOLIAH Weight Indicator-Repeater for Hazardous Areas Specifications
I/O Section:
TAKE NOTE: |
DGT60R Functions:
|
Functions:
Main Certifications:
|
Parts
Part # | Description |
---|---|
Available versions | |
DGT60BC3GD-1 | ATEX 3GD weight indicator with 60mm LED display. IP68 stainless steel case and 5-key keypad. Protection mode: ATEX II 3G Ex nR IIC T6 Gc X for gases and ATEX II 3D Ex tc IIIC T85øC Dc IP68 X for dust. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT). |
DGT60AN3GD-1 | ATEX 3GD weight indicator with 60mm LED display and analogue output. IP68 stainless steel case and 5-key keypad. Protection mode: ATEX II 3G Ex nR IIC T6 Gc X for gases and ATEX II 3D Ex tc IIIC T85øC Dc IP68 X for dust. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT). |
DGT60PB3GD-2 | ATEX 3GD weight indicator with 60mm LED display and Profibus. IP68 stainless steel case and 5-key keypad. Protection mode: ATEX II 3G Ex nR IIC T6 Gc X for gases and ATEX II 3D Ex tc IIIC T85øC Dc IP68 X for dust. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT). |
DGT60R3GD-2 | ATEX 3GD weight repeater with 60mm LED display. IP68 stainless steel case and 5-key keypad. Protection mode: ATEX II 3G Ex nR IIC T6 Gc X for gases and ATEX II 3D Ex tc IIIC T85øC Dc IP68 X for dust. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR, ES and IT). |
Options
Part # | Description |
---|---|
Approval for sale to third parties | |
KCEM | Plates and Welmec form for legal trade use of a scale. NET PRICE. Service available in combination with a Dini Argeo indicator. |
ECEM-AU | Single platform/scale legal-for-trade approval for Australia. |
Optional power supply cords | |
EXACB4 | 4x0.5 mmý armoured cable (suitable for Ex zones). PVC inner sheath. Armour: galvanised steel wire braid. Outer sheath PVC, diameter 7.3 mm. Temperature range: -30 / +80 øC. Minimum bending radius >/= 10 x O.D. _/m |
Options for ATEX version | |
ZBA1S | Intrinsic protection three channel Zener barrier. Specific for connection to load cells, for mounting on DIN rail in a safe area, or in a flame-proof case. Marking: ATEX/IECEx II (1) GD [Ex ia Ga] IIC [Ex ia Da] IIIC. Manual and ATEX UE CONFORMITY DECLARATIONS (available in EN, DE, FR, ES and IT). |
ZBINST | Installation of the ZBA1S / PFB485EX zener barrier inside the indicator case. Note: The cable (LCCB for barrier ZBA1S, RSCBTW for barrier PFB485EX) of the desired length must also be purchased. NET PRICE. |
LCCB | Shielded cable 6x0.25 mmý (suitable for Ex zones). PVC inner sheath. Tinned copper braid shielding. PVC outer sheath, diameter 5.8 mm. Temperature range: -40 / +80 øC. Minimum bending radius >/= 6 x O.D. _/m |
PFB485EX | Protection barrier for RS485, for direct connection in safe area. Max cable length: 200m. |
RSCBTW | 4-core twisted shielded cable (2x2x0.34 mmý), for RS485 communication or analogue output. Polyolefin inner sheath. Tinned copper braid shielding. Outer sheath PVC, diameter 7mm. Temperature range: -30 / +80 øC. Minimum bending radius >/= 6 x O.D. _/m |
DCATEX3GD | Declaration of ATEX conformity of whole. Ex II 3G IIC T6 Gc X and Ex II 3D IIIC T115øC Dc X system, with relative label of whole system, for ATEX certified or NOT ATEX certified Dini Argeo indicator (in the latter case to be installed in a safe area) connected to a mechanical structure with ATEX load cells (each load cell must be certified with CCATEX or CCATEX3GD option). Provided with descriptive document of the assembly and ATEX EU declaration of conformity of the assembly (EN, DE, FR, ES and IT). |
Communication Interfaces | |
SETHDIN-1 | RS232 / RS485 / Ethernet converter. Modbus RTU / Modbus TCP/IP (if applicable). Connectable to all Dini Argeo weight indicators via the serial port. ABS housing for DIN rail. With PCB, screw terminals, plastic box and UL marked labels (if applicable). |
OBRF2G4-3GD | 2.4 GHz radio frequency module for ATEX 2 & 22 zones. ABS IP66 case, 3 m shielded cable, and power supply from indicator. Protection: ATEX II 3G Ex ec IIC T6 Gc X for gases and ATEX II 3D Ex tc IIIC T85øC Dc IP66 X for dust. Max. functioning distance, in appropriate environmental and installation conditions: 45 m indoors, 140m outdoors. 39 configurable channels. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR and IT). |
ALMEM-1 | Alibi memory (fiscal memory, max 120.000 weighs) for approved weight transmission to PC/PLC or data recording on MMC/USB. Built-in real time clock to print the date/time with PCB, screw terminal, plastic box and UL-marked labels (if applicable). |
ETHD | Built-in Ethernet interface. Speed from 10 to 100 Mbps, TCP, UDP, IP, ARP, ICMP, Ethernet Mac protocols. |
OBWIFI3GD-4 | WIFI module for ATEX zones, with ABS IP66 case, 3 m shielded cable, and power supply from indicator. Protection: ATEX II 3G Ex ec IIB T6 Gc X for gases and ATEX II 3D Ex tc IIIC T85øC Dc IP66 X for dust. Max. functioning distance, in appropriate environmental and installation conditions: 30m indoors, 70m outdoors. Provided with safety instructions and the ATEX EU declaration of conformity (EN, DE, FR and IT). |
Connection cables | |
RSCBTW | 4-core twisted shielded cable (2x2x0.34 mmý), for RS485 communication or analogue output. Polyolefin inner sheath. Tinned copper braid shielding. Outer sheath PVC, diameter 7mm. Temperature range: -30 / +80 øC. Minimum bending radius >/= 6 x O.D. _/m |
ETHCBEX | Multi-core cable (4x2xAWG24) suitable for Ethernet connections in Ex-zones (connectors and cable gland only installed with S6 service). First shield: aluminium/polyester tape, second shield: tinned copper braid (coverage = 85% - EMC 89/336). Outer sheath: PVC, diameter 6.3mm. Temperature range: -30 / +80 øC. Minimum bending radius >/= 8 x O.D. Minimum length 10 m. _/m |
Date&Time option | |
DFCLK | Real time clock for printing/displaying of date and time. With UL marked PCB, screw terminal, plastic box and labels (if applicable). |
Columns, supports brackets, visors | |
STFR-1 | AISI 304 stainless steel fixing bracket with adjustable inclination. For weight indicator wall mounting. |
PG cable glands | |
PG9EX | 10 PG9 metallic cable gland set for ATEX indicators. Complete with ferrules and seals. Cable diameter: 4 to 8 mm. |
Other options | |
TECSUP | Technical assistance by telephone upon request. |