Dini Argeo "DFWIECEX" weight indicator, IECEx and ATEX certified, for Zones 1 and 21, 2 and 22.
LCD display with RGB backlight
State-of-the-art, high-speed X-Core CPU ideal for handling fast and accurate weighing, filling or dosing processes
ASCII/RTU Modbus
Comprehensive range of industrial interfaces, at your choice: - Intrinsically safe digital I\O - Intrinsically safe analog output - Up to 3 intrinsically safe bi-directional RS485 serial ports - Bluetooth
NOTE: All of the above interfaces are certified for use in hazardous areas
The DFWIECEX weight indicator represents the state of the art for weighing in environments with a high risk of explosion. Thanks to the RGB backlit display, to the powerful processor and above all to the main interfaces available, all intrinsically safe, DFWIECEX allows the integration of weighing within production processes, directly in hazardous areas, driving solenoid valves and communicating with PLCs and other devices. IECEx and ATEX certified and approved for legal-for-trade use.
Protection:- for Gas: Ex ib [ib Gb] [ia Ga] IIC T4 Gb- for dust: Ex tb [ib Db] [ia Da] IIIC T135°C Db - ATEX: II2(2)G(1)G - ATEX: II2(2)D(1)D - Ta 0°C / +50°C
High contrast RGB backlit display, with 6 digits of 25 mm. Brightness adjustable from keyboard.
17-key waterproof keyboard
AISI304 stainless steel casing, with IP65 and IP68 certified protections.
Minimum measurement range (internal use): 0.01 µV/d
4 load cell inputs, with selectable operating mode: - Single scale (use of only one input) - 4-channel digital junction box (use of multiple load cell inputs)
Metrological approval: 10,000e or multi range 3x3000e @ 0.3µV/e.
Connection up to 8 load cells of 350Ohm.
Possibility of direct connection to load receptor installed in Zone 0 and 20.
1 Intrinsically safe RS485 serial port as standard, for two-way communication with PLCs, PCs or devices in explosive zones.
Power supply of your choice (see options table): - Through Dini Argeo power supply, 110-230 Vac or 24 Vac - 24 Vdc - Through Dini Argeo external battery, in stainless steel, with autonomy of about 40 h (Connection/disconnection directly in explosive zone and charging in safe area)
NOTE: Autonomy may be reduced depending on load reception system, connected communication accessories, and backlight configuration.
Dimensions: 280x143x185 mm.
Available cable glands: 2 x PG9 as standard, 1 PG supplied (not mounted) and setup for a further 2 optional PG9s.
OPTIONAL DIGITAL INPUTS/OUTPUTS:
Intrinsically safe 4-input, 4-output digital card with the following specifications:Inputs- Ui: 18 V - Ri: 214 Ω - R input: 859 Ω Electronic relay outputs- Ui: 18 V - Pi: 1,75 W In: 70 mA
Intrinsically safe power supply terminal, for piloting devices in ATEX zone or push-button panel.Output voltage 6V, max current 300mA.
NOTE: by using the available power supply terminal, it is possible to manage the push button panel code EXPHBN in a direct way, even in a safe area, without protection barriers.
OPTIONAL ANALOG OUTPUT:
Intrinsically safe analog output, programmable at 0...10Vdc, 0...20mA or 4...20mA.
NOTE: It is possible to transmit the signal directly to the safe area using the intrinsically safe protective barrier, code PFANOUTEX for analog output in 0...20mA (or 4...20mA) configuration.
The analogue output of DFWIECEXAN is an active analogue output, which is why it must not be powered. The resistance of analogue input shall be: - If the output signal is in voltage: Rmin=1K - If the output signal is in current: Rmax=300ohm
RS485 SERIAL PORT
2 Optional intrinsically safe RS485 serial ports for communication with repeaters and other devices. - ASCI protocol - Programmable weight string and read command - Modbus RTU
NOTE: it is possible to transmit data directly to the safe area using the protective barrier code PFB485EX
Main certifications:
EU Type Examination Certificate (EN 45501:2015)
OIML R76
EN/IEC 60079-0
EN/IEC 60079-11
EN/IEC 60079-5
EN/IEC 60079-31
Certification according to ATEX directive 2014/34/EU and in compliance with IECEx certification scheme, group II category 2GD according to EN/IEC 60079-0, EN/IEC 60079-11, EN/IEC 60079-5, EN/IEC 60079-31.
IECEX and ATEX certified weight indicator for zones 1, 21, 2, 22.
Protection: Ex II 2(2)G(1)G Ex ib [ib Gb] [ia Ga] IIC T4 Gb X for gas and Ex II 2(2)D(1)D Ex tb [ib Db] [ia Da] IIIC T135øC Db X for dust (Ta=0øC/+50øC). Always combine with IECEXPW power supply or IECEXB battery. Includes printed safety instructions and EU ATEX declaration of conformity (EN, DE, FR, ES, IT).
IECEX and ATEX certified weight indicator for zones 1, 21, 2, 22.
With integrated, intrinsically safe analogue output and additional cable gland.
Protection: Ex II 2(2)G(1)G Ex ib [ib Gb] [ia Ga] IIC T4 Gb X for gas and Ex II 2(2)D(1)D Ex tb [ib Db] [ia Da] IIIC T135øC Db X for dust (Ta=0øC/+50øC). Always combine with IECEXPW power supply or IECEXB battery. Includes printed safety instructions and EU ATEX declaration of conformity (EN, DE, FR, ES, IT).
Intrinsically safe RS485 serial port , for communication in ATEX zone. Maximum communication distance 200m. (NOTE: for direct communication with devices in safe area, it is necessary to use PFB485EX protective barrier.)
Card with 4 opto-isolated digital inputs and 4 outputs , intrinsically safe, for piloting devices in hazardous areas.
To be used in conjunction with intrinsically safe voltages. For further information consult the instruction manual.
IECEx and ATEX power supply for DFWIECEX with 110-230Vac input.
Includes input cable for connection to the network (6m) and output cable for connection to the indicator (3m).
Protection: Ex II 2(2)G Ex q [ib Gb] IIC T4 Gb X for gas and Ex II 2(2)D Ex tb [ib Db] IIIC T135øC Db X for dust (Ta=0øC/+50øC). Please refer to the instruction manual for more information. A printout of the safety instructions and the EU declaration of conformity ATEX (EN, DE, FR, ES, IT) is included.
IECEx and ATEX power supply for DFWIECEX with 24V input (AC or DC).
Includes input cable for connection to the network (6m) and output cable for connection to the indicator (3m).
Protection: Ex II 2(2)G Ex q [ib Gb] IIC T4 Gb X for gas and Ex II 2(2)D Ex tb [ib Db] IIIC T135øC Db X for dust (Ta=0øC/+50øC). Please refer to the instruction manual for more information. A printout of the safety instructions and the EU declaration of conformity ATEX (EN, DE, FR, ES, IT) is included.
IECEx and ATEX external rechargeable battery for DFWIECEX, capacity 9Ah, with quick-release connector. Protection: Ex II 2(2)G Ex ib [ib Gb] IIC T4 Gb X for gas and Ex II 2(2)D Ex ib [ib Db] IIIC T135øC Db X for dust (Ta=0øC/+50øC). Charging in safe area through battery charger code IECEXCB. See instruction manual for more information. Printout of safety instructions and EU declaration of conformity ATEX (EN, DE, FR, ES, IT) is included. To be combined with BTCBIECEX cable for connection to DFWIECEX indicator.
IECEXB battery charging kit (recharge in safe area). Composed by certified battery charger mod. IECEXCB and power supply with 230Vac socket (VDE cable)
Blue shielded cable 6x0.22 mmý, only for EX i (2GD) assemblies. PVC inner sheath. Tinned copper braid shielding. Polyurethane outer sheath, diameter 5.8 mm. Temperature range: -40 / +80 øC. Minimum bending radius >/= 7 x O.D. _/m
EX 2GD hand control with 2 buttons and cable gland (optional connection cable). Protection II 2G Ex db eb IIC T6 Gb for gases, II 2D Ex tb IIIC T80øC Db for dust.
Printed EU declaration of conformity, EU certificate of verification, test certificate and metrological book (free download from our website, only for approved CE-M products). NET _.
Declaration of ATEX conformity of the assembly. Ex II 2G IIC T4 Gb X and Ex II 2D IIIC T135øC Db X system (Ta=0øC/+40øC), with relative label of whole system, for Dini Argeo DFWIECEX weight indicator connected a mechanical structure with ATEX load cells (each cell must be certified with CCATEX option). Provided with descriptive document of the assembly and ATEX EU declaration of conformity of the assembly (EN and IT).
Installation of the ZBA1S / PFB485EX zener barrier inside the indicator case. Note: The cable (LCCB for barrier ZBA1S, RSCBTW for barrier PFB485EX) of the desired length must also be purchased. NET PRICE.
Protection barrier for analog current output, 0...20mA or 4...20mA configuration, for direct connection in safe area. Max cable length: 200m.
It requires an external 24Vdc power supply.